beautypg.com

Technical data – KROHNE OPTISONIC 6300 P-6400 EN User Manual

Page 81

background image

TECHNICAL DATA

8

81

OPTISONIC 6300 P

www.krohne.com

03/2013 - 4000972603 - MA OPTISONIC 6300 P R03 en

Status output

Status output

Status output

Status output

Isolation

The output is galvanically isolated from the other circuits.

Function and settings

Settable as automatic measuring range change, indicator for direction of

flow, overflow, error, operating point or empty pipe detection

Status and/or control: ON or OFF

Operating data

Active

U

int

= 15 VDC

I ≤ 20 mA

open:

I ≤ 0.05 mA

closed:

U

0, nom

= 15 V at I = 20 mA

Passive

U

ext

≤ 32 VDC

I ≤ 100 mA

open:

I ≤ 0.05 mA at U

ext

= 32 VDC

closed:

U

0, max

= 0.2 V at I ≤ 10 mA

U

0, max

= 2 V at I ≤ 100 mA

Current inputs

Current inputs

Current inputs

Current inputs

Isolation

The inputs are not galvanically isolated from the other circuits.

Function

Input of temperature, used for energy calculation in combination with

flow measurement

Range: -50...500°C / -58...932°F (default: 0...120°C / -32...248°F)

Operating data

Active

U

int

= 15 VDC

I ≤ 22 mA

I

max

= 26 mA (electronically limited)

U

0, min

= 9 V with I ≤ 22 mA

No HART

®

Passive

U

ext

≤ 32 VDC

I ≤ 22 mA

I

max

= 26 mA (electronically limited)

U

0, max

= 5 V with I ≤ 22 mA

No HART

®

Approvals and certificates

CE

CE

CE

CE

This device fulfills the statutory requirements of the EC directives.

The manufacturer certifies successful testing of the product by applying

the CE mark.

Electromagnetic compatibility Directive: 2004/108/EC

Harmonized standard: EN 61326-1: 2006

Low voltage directive

Directive: 2006/95/EC

Harmonized standard: EN 61010: 2001

Other approvals and standards

Other approvals and standards

Other approvals and standards

Other approvals and standards

Protection category acc. to

IEC 529 / EN 60529 /

NEMA 250/2003

Sensor: IP 67 / NEMA 6

Converter: IP 65 / NEMA 4

Trunk on wheels: IP 67 / NEMA 6

Power adapter: IP 40 / NEMA 1

Shock test sensor

IEC 60068-2-27

Vibration test sensor

IEC 60068-2-64