5.6 I/O cable
To use the available inputs and outputs of the converter, you need an optional I/O box. The I/O
box is available in two versions (standard I/O functions and heat measurement version).
• Plug the connector 2 of the I/O box 3 in the connector 1 of the converter. Then use the
connectors 4 to setup the wanted I/O, as shown in the connection diagrams on the next
pages.
Versions of I/O box
Figure 5-5: I/O box
1 I/O connector on converter
2 Connector of I/O box
3 I/O box with screw terminals for 1 mm
2
wiring
4 Screw terminal pin 1...15
Screw terminal
pin
Standard I/O box
I/O box with heat option
1
Frequency / pulse output D
Frequency / pulse output D
2
Frequency / pulse output D-
Frequency / pulse output D-
3
Status output X
Status output X
4
Status output X-
Status output X-
5
Current output C+
Current output C+
6
Current output C
Current output C
7
Current output C-
Current output C-
8
Current input A+
Temperature sensor 1
(PT 100, 4 wire connection)
9
Current input A-
10
Current input B+
11
Current input B-
12
Not connected
Temperature sensor 2
(PT 100, 4 wire connection)
13
Not connected
14
Not connected
15
Not connected
Table 5-1: Terminals of I/O box