OPTISONIC 6300 P

www.krohne.com

03/2013 - 4000972603 - MA OPTISONIC 6300 P R03 en

Operating conditions

Temperature

Temperature

Temperature

Temperature

Process temperature

Standard version: -40...+120°C / -40...+248°F

Ambient temperature

Sensor: -40...+70°C / -40...+158°F

Signal converter: -20…+55°C / -4…+131°F

(Humidity: 5...80%, non condensing)

Storage temperature

-30…+80°C / -22…+176°F

(Humidity: 5...80%, non condensing)

Pipe specifications

Pipe specifications

Pipe specifications

Pipe specifications

Material

Metal, plastic, ceramic, asbestos cement, internal / external coated

pipes (coatings and liners fully bonded to pipe wall)

Pipewall thickness

< 200 mm / 7.87"

Liner thickness

< 20 mm / 0.79"

Media properties

Media properties

Media properties

Media properties

Physical condition

Liquids

Viscosity

< 100 cSt (general guideline)

For detailed information please contact your local representative.

Permissible gas content

(volume)

≤ 2%

Permissible solid content

(volume)

≤ 5%

Recommended flow velocity

0.5...20 m/s

Installation condititions

Measurement configuration

Single pipe, single path

Single pipe, dual path

Dual pipe, dual path

Inlet run

≥ 10 DN straight length

Outlet run

≥ 5 DN straight length

Dimensions and weights

For detailed information refer to

Dimensions and weights

on page 82.

Materials

Sensor

Anodized aluminum (rail)

Converter

Polyamide PA12, covered with TPE soft touch layer on the sides

Trunk on wheels

Polypropylene