beautypg.com

Electrical connections, Pulse / frequency output – KROHNE OPTISONIC 6300 P-6400 EN User Manual

Page 49

background image

ELECTRICAL CONNECTIONS

5

49

OPTISONIC 6300 P

www.krohne.com

03/2013 - 4000972603 - MA OPTISONIC 6300 P R03 en

Pulse/frequency output passive

• U

ext

≤ 32 VDC

• f

max

in operating menu set to f

max

≤ 100 Hz:

I ≤ 100 mA
open:
I ≤ 0.05 mA at U

ext

= 32 VDC

closed:
U

0, max

= 0.2 V at I ≤ 10 mA

U

0, max

= 2 V at I ≤ 100 mA

• f

max

in the operating menu set to 100 Hz < f

max

≤ 10 kHz:

I ≤ 20 mA
open:
I ≤ 0.05 mA at U

ext

= 32 VDC

closed:
U

0, max

= 1.5 V at I ≤ 1 mA

U

0, max

= 2.5 V at I ≤ 10 mA

U

0, max

= 5.0 V at I ≤ 20 mA

• If the following maximum load resistance R

L, max

is exceeded, the load resistance R

L

must be

reduced accordingly by parallel connection of R:
f ≤ 100 Hz: R

L, max

= 47 kΩ

f ≤ 1 kHz: R

L, max

= 10 kΩ

f ≤ 10 kHz: R

L, max

= 1 kΩ

• The minimum load resistance R

L, min

is calculated as follows:

R

L, min

= (U

ext

- U

0

) / I

max

• Can also be set as a status output; for the electrical connection, see status output connection

diagram.

Pulse/frequency output active

• U

nom

= 15 VDC

• f

max

in operating menu set to f

max

≤ 100 Hz:

I ≤ 20 mA
open:
I ≤ 0.05 mA
closed:
U

0, nom

= 15 V at I = 20 mA

• f

max

in the operating menu set to 100 Hz < f

max

≤ 10 kHz:

I ≤ 20 mA
open:
I ≤ 0.05 mA
closed:
U

0, nom

= 13.5 V at I ≤ 1 mA

U

0, nom

= 12.5 V at I ≤ 10 mA

U

0, nom

= 9.0 V at I ≤ 20 mA

INFORMATION!

Pulse / frequency output

Any connection polarity.

Galvanically isolated.