TECHNICAL DATA

8

79

OPTISONIC 6300 P

www.krohne.com

03/2013 - 4000972603 - MA OPTISONIC 6300 P R03 en

Electrical connections

Power supply

Adapter for 100…240 VAC (-10% / +10%), 47...63 Hz

Adapter voltage: 13.2 V

Maximum power consumption: 10 W (25 W during charging)

Charging time: 8 hours

Battery type: Lithium polymer

Battery lifetime:

Battery lifetime:

Battery lifetime:

Battery lifetime:

Measuring operation (display at 50% brightness): 14 hours

Signal cable

double shielded, internal triax, length: 3 m / 15 ft

USB ports

1x for PC, 1x for memorystick

Inputs / outputs

15 pin connector for I/O interfacing with optional I/O box

Optional: PT100 input:

Optional: PT100 input:

Optional: PT100 input:

Optional: PT100 input:

Function: PT 100 temperature input by 2x KROHNE TT30C temperature

transmitters build into an I/O box

For specifications see TT30C datasheet.

Optional: temperature input:

Optional: temperature input:

Optional: temperature input:

Optional: temperature input:

Function: temperature input by 2x KROHNE TSR-W 30 clamp-on

temperature sensors only in combination with I/O box with temperature

transmitters.

For specifications see TSR-W 30 datasheet.

Inputs and outputs

Connections

Inputs and outputs can only be connected using the optional I/O box.

Description of used

abbreviations

U

ext

= external voltage

R

L

= load + resistance

U

o

= terminal voltage

I

nom

= nominal current

Current output

Current output

Current output

Current output

Isolation

The output is not galvanically isolated from the other circuits.

Output data

All analog measurement parameters like volume and mass flow (at

constant density), flow speed, speed of sound, gain, signal to noise ratio,

reliability of flow measurement, quality of acoustic signal, thermal

energy (requires input of temperature (2x)).

Settings

Q = 0%: 0…20 mA; Q = 100%: 10…21.5 mA

Error identification: 0…22 mA

Operating data

Active

U

int,nom

= 15 VDC

I ≤ 22 mA

R

L

≤ 450 Ω

Passive

U

ext

≤ 32 VDC

I ≤ 22 mA

U

0

≥ 1.8 V at I = 22 mA