3

INSTALLATION FOR FLOW MEASUREMENT

16

OPTISONIC 6300 P

www.krohne.com

03/2013 - 4000972603 - MA OPTISONIC 6300 P R03 en

Position of pump

Determine data and dimensions of pipe

• Use the supplied tape measure to determine the outside diameter of the pipe.
• Determine the pipe wall thickness. A pipe wall thickness gauge or pipe tables can be used for

this.

• Find out what the material of the pipe is.
• If the pipe has a liner, find out the liner material and the thickness of the liner.

CAUTION!
Never install the flowmeter at the suction side of a pump in order to avoid cavitation or flashing
in the flowmeter.

Figure 3-7: Position of pump

CAUTION!
The next data must be available before proceeding with Step 2.