116

The modulation source is set to internal.

SOURce[1]:FM:INTernal:FUNCtion

Set

Query

Description

Sets the shape of the modulating waveform from
sine, square or ramp. The default shape is sine.

Note

Square waveforms have a 50% duty cycle. Ramp
waveforms have a symmetry of 100%.

Syntax

SOURce[1]:FM:INTernal:FUNCtion
{SINusoid|SQUare|RAMP }

Example

SOUR1:FM:INT:FUNC SIN

Sets the FM modulating wave shape to sine.

Query Syntax

SOURce[1]:FM:INTernal:FUNCtion?

Return Parameter SIN

Sine

SQU

Square

RAMP

Ramp

Query Example

SOUR1:FM:INT:FUNC?
>SIN

The shape for the modulating waveform is Sine.

SOURce[1]:FM:INTernal:FREQuency

Set

Query

Description

Sets the frequency of the internal modulating
waveform only. The default frequency is 10Hz.

Syntax

SOURce[1]:FM:INTernal:FREQuency
{|MINimum|MAXimum}

Parameter

2 mHz ~ 20 kHz

Example

SOUR1:FM:INT:FREQ +1.0000E+02

Sets the modulating frequency to 100Hz.

Query Syntax

SOURce[1]:FM:INTernal:FREQuency?
[MINimum|MAXimum]