86
9. Survey Pro’s On-Board Version
Survey Pro is used on board a Nikon Nivo or Spectra Precision FOCUS total
station. After you have powered on the instrument, wait until the screen
displays the desktop. Then do the following:
• Double-tap the Survey Pro icon:
. Survey Pro starts initializing the
instrument. The Level Bubble screen is then shown (see screen example).
• Level the instrument and enable or disable the compensator, as required.
• Tap
when done. This opens the
Quick Shot screen.
You may take measurements with Survey Pro without opening a job. You may
also create or open a job where you can collect all your measurements and/or
use as reference other measurements you collected earlier in that job.
NOTE: The onboard version of Survey Pro will always start with no job open regardless
of whether you ended your last Survey Pro session with a job open or not.
Working With
No Job Open
The
Quick Shot screen you get at startup can be split into different parts:
• Command bar ([1] to [9])
• Function buttons ([10] to [13])
• Result pane ([14])
• Target management and EDM measurement mode ([15])
• Other control buttons ([16] to [18]).
Robotic Instrument:
[1] [2] [3] [4] [5] [6] [7] [8] [9]
[10]
[16] [17] [18]
[11]
[12]
[13]
[14]
[15]