beautypg.com

Station setup on unknown point, resection method – Spectra Precision Survey Pro v5.4 User Manual

Page 49

background image

39

As previously explained for

BS Azimuth, you can in the same way check

the setup either

By Angle or By Point (see Check the Setup above).

You can also use the

By Distance option. Just make sure the instrument

is still aimed in the direction of the backsight point and tap

Check. The

measured horizontal and vertical distance errors are reported on the
screen. They should be as close a possible to zero.

• If you are satisfied with the read values, tap

Finish. You can now start

measuring new points.

3. If you choose

New Point:

– Place a target at the unknown (new) backsight point.
– Aim the instrument at this point.

– Enter the known or an assumed value of azimuth along this direction.

– Specify the type of target used at the backsight point (

Fixed Target or

Roving Target).

– Using

, select the name of this target. As a result, the

HR field is

updated to provide the height of this target. Update the height value if
necessary.

– Tap

Measure & Set to measure the new point and set the backsight.

NOTE: If the equipment used is unable to set the backsight circle, the button is

labeled “

Measure & Read” instead of “Measure & Set”.

Enter a name and description for the new backsight point.

Tap

to store the point.

Review the summary of the station setup, as shown on the screen. If it’s
not as expected, tap

Back and resume the setup.

– If the setup is fine, tap

Finish. You can now start measuring new points.

Station Setup on Unknown Point, Resection Method

The resection method is illustrated below.

PT1

PT3

PT2

PT4