Spectra Precision Survey Pro v5.4 User Manual
Page 65
55
NOTE: You can tap the
Wait xx button to accept the point before the minimum
duration has expired. You will in return be informed that the minimum duration is
not yet met, at which point you can discard the warning by tapping
Accept anyway.
•
Average for cleared: Screen type [2] will be displayed for an unlimited
period of time, until you tap
Accept. Point collection is then complete,
unless some other acceptance criteria are not met in which case you will
see screen type [3] after you tap
Accept. You can also choose to accept the
point before the wait time expires.
•
Automatically accept when criteria is met checked: The use of this parameter
makes sense when it is combined with
Average for checked. Survey Pro will
automatically store the point at the end of the averaging time, unless some
other acceptance criteria are not met. In that case, at the end of the count
down, the
Accept button will be restored on the screen and when you tap
on it, you will see screen type [3].
When screen type [3] is displayed, you can either ignore the warning message
(tap
Accept Anyway), or ask for more data collection on the point (tap Keep
Measuring) until you are satisfied with the collected data (you will then tap
Accept to end the point collection).
[1]
[3]
[2]