AIRCART OPERATOR’S MANUAL 74
Once a sample is collected (the larger the sample the more accurate the calibration) Select
“END”, this will stop the roller.
Weigh the filled calibration bucket, enter the weight of the product caught. Toggle the “LEFT”
and “RIGHT” keys moving the arrow under the desired digit to edit, select “ENTER” to modify
the digit. Toggle between “INC” and “DEC” to change the digit value.
Once the weight is entered, toggle to the RIGHT until “SEND” appears. Select “SEND” to save
the calibration number to the Viper Pro™. Repeat the steps for the remaining meters.
To turn off remote calibration console, press and hold the blue power button until the
monitor powers down.
NOTE: DO NOT include the weight of the calibration bucket in the metered weight value.
Information is instantly sent to the Seed Hawk Viper Pro™ monitor.
After all meters are calibrated Power down the Remote tank calibration console and disconnect
from tank harness. It is recommended to repeat the calibration to avoid operator error.
DO NOT leave the Remote tank calibration console attached to the tank exposed to the
weather. REFER TO THE CALIBRATION GUIDE FOR ALTERNATIVE TIPS AND
RECOMMENDATIONS FOR CALIBRATING THE AIRCART METERS.