Once  a  sample  is  collected  (the  larger  the  sample  the  more  accurate  the  calibration)  Select 
“END”, this will stop the roller. 









Weigh the filled calibration bucket, enter the weight of the product caught. Toggle the “LEFT” 
and “RIGHT” keys moving the arrow under the desired digit to edit, select “ENTER” to modify 
the digit. Toggle between “INC” and “DEC” to change the digit value.  









Once the weight is entered, toggle to the RIGHT until “SEND” appears.  Select “SEND” to save 
the calibration number to the Viper Pro™.  Repeat the steps for the remaining meters. 








To  turn  off  remote  calibration  console,  press  and  hold  the  blue  power  button  until  the 
monitor powers down. 
 
NOTE:
 DO NOT include the weight of the calibration bucket in the metered weight value.  
Information is instantly sent to the Seed Hawk Viper Pro™ monitor. 
After all meters are calibrated Power down the Remote tank calibration console and disconnect 
from tank harness.  It is recommended to repeat the calibration to avoid operator error. 
DO  NOT  leave  the  Remote  tank  calibration  console  attached  to  the  tank  exposed  to  the 
weather.    REFER  TO  THE  CALIBRATION  GUIDE  FOR  ALTERNATIVE  TIPS  AND 
RECOMMENDATIONS FOR CALIBRATING THE AIRCART METERS.