Seed Hawk AIRCART 2013 User Manual
Page 52
SEED HAWK
®
AIRCART OPERATOR’S MANUAL 47
5. Sensor Settings: Specific information about each
sensor installed on the MuxBus system can be viewed
by placing the highlight bar on the sensor and pressing
“Settings”. The monitor will display the sensor type
number, communication speed, and serial number.
Sensors with a user settable value have a dialog box
that can be accessed to enter a value. To do this,
navigate to the dialog box and press “Enter”. A keypad
dropdown box will appear. Use the spinner dial or
navigation keys to highlight the individual numbers you
want to enter starting with the left most value.
NOTE: You must press the spinner dial to select
individual numbers. You must press the “Enter” button
to save the complete value.
6. Ignore/Revive: You can temporarily disable
sensors by placing the highlight bar on the
desired sensor selecting Ignore. Re‐enable that
sensor by placing the highlight bar on the
sensor and selecting Revive. This is used to
disable a sensor if a part of the system is not
being used such as a bin that is left empty. By
ignoring the sensor you will eliminate unwanted
alarms.