The Menu Settings screen lists 12 choices: 

 

1.  MuxBus  Sensor  Setup:  This  is  used  to  install  and  remove

 

sensors  that  operate  on  the 

MuxBus  network.  These  include  the  ground  speed  sensor,  the  Fan  sensors,  the  Bin

 

Level 

sensors, pressure and flow sensors. 

 

NOTE: The VAR Controller listed is not used in this application 
 
NOTE: The pressure sensor listed as a MuxBus sensor is available but a different sensor than 
the Packing Pressure sensor. That sensor is connected to the hydraulic drive control module 
and is communicated on the CAN network. It is called Shank Pressure in the layout item select 
menu.

 


2.  Global  Settings:  Use  this  menu  selection  to 
set  the  units  of  measure,  language,  implement 
width,  the  volume  of  the  alarm,  the  backlight 
and  contrast  of  the  screen,  and  the  master 
switch mode 

 
 

 

3. Restore Settings to Defaults: This is used to 
return all settings to factory defaults. (Warning?) 



 
 
 

 

4.  Ground  Speed  Calibration:  This  is  used  to 
perform  a  field  calibration  for  accurate  ground 
speed  input.  The  accuracy  of  this  calibration 
affects application rates, acre accumulation, and 
ground speed.