 AIRCART OPERATOR’S MANUAL                                                                              57 

7.3.6

 CLEAR FIELD ACRES 


Choosing  this  item  allows  you  to  clear  the  accumulated  field  acres.  A  dialog  box  will  appear 
verifying your selection. Once verified the field acres cannot be restored. 
NOTE: Total acres cannot be cleared from the settings menu. Contact your Seed hawk Dealer 
for information on clearing the total acres register. 



 







7.3.7

 RATE CONTROLLER METER SETUP 


This selection allows the operator to enter setup 
information for the meters. The default screen is 
meter  1.  Other  meters  can  be  selected  by 
pressing the soft key for the desired meter. 
 
1.  Pulses  per  Rev:  This  is  the  number  of  pulses 
generated  by  the  meter  sensor  equal  to  1 
revolution  of  the  meter  roller.  This  value  is  set 
by  default  but  can  be  manually  entered.  The 
default  value  for  a  hydraulic  drive  system  is 
60.31. 
 
2. Low alarm point: This is the minimum meter rpm speed the meter can turn before the “low 
meter rpm”
 or “meter stopped” alarms will display. The default value is 0.5 RPM. 
 
3.  Weight/Rev:  This  value  is  determined  by  the  Meter  calibration  procedure  or  it  can  be 
manually entered. 
 
4. Increment:  This value is the increment value for on the go rate adjustments when seeding. 
The default value is 5 .00 lb/ac
5.  OK/Cancel:  Select  “OK”  to  save  any  changes  made.  Select  “Cancel”  to  ignore  any  changes 
made.