AIRCART OPERATOR’S MANUAL 57
7.3.6
CLEAR FIELD ACRES
Choosing this item allows you to clear the accumulated field acres. A dialog box will appear
verifying your selection. Once verified the field acres cannot be restored.
NOTE: Total acres cannot be cleared from the settings menu. Contact your Seed hawk Dealer
for information on clearing the total acres register.
7.3.7
RATE CONTROLLER METER SETUP
This selection allows the operator to enter setup
information for the meters. The default screen is
meter 1. Other meters can be selected by
pressing the soft key for the desired meter.
1. Pulses per Rev: This is the number of pulses
generated by the meter sensor equal to 1
revolution of the meter roller. This value is set
by default but can be manually entered. The
default value for a hydraulic drive system is
60.31.
2. Low alarm point: This is the minimum meter rpm speed the meter can turn before the “low
meter rpm” or “meter stopped” alarms will display. The default value is 0.5 RPM.
3. Weight/Rev: This value is determined by the Meter calibration procedure or it can be
manually entered.
4. Increment: This value is the increment value for on the go rate adjustments when seeding.
The default value is 5 .00 lb/ac.
5. OK/Cancel: Select “OK” to save any changes made. Select “Cancel” to ignore any changes
made.