 AIRCART OPERATOR’S MANUAL                                                                              46 

2.  Plug  in  the  sensors:  in  the  order  listed  on  the 
menu.  Different  sensors  have  different  types  and 
cannot  be  learned  to  the  wrong  location  but  the 
first fan sensor plugged in will be assigned to Fan 1. 
The first Bin Level sensor plugged in will be learned 
to Bin 1, etc. The speed, pressure, and flow sensors 
all  use  the  same  type  sensor  code  so  the  first  one 
plugged in will be the speed sensor, etc. 
 


3. Add a sensor:  Individual sensors can be added to 
the MuxBus system at any time. Place the highlight 
bar on the sensor you want to add (Fan 2 in the 
example) and press install. Then plug in the sensor. 
Multiple sensors can also be added using this 
method but you need to position the highlight bar 
on each new sensor and press “Install” before 
plugging in each sensor. 

 
 
 

4.  Remove  a  sensor:  Individual  sensors  can  be 
removed by placing the highlight bar on the sensor 
you want to remove and pressing “Remove”. Then 
unplug the sensor.