Seed Hawk AIRCART 2013 User Manual
Page 51
![background image](/manuals/364506/51/background.png)
SEED HAWK
®
AIRCART OPERATOR’S MANUAL 46
2. Plug in the sensors: in the order listed on the
menu. Different sensors have different types and
cannot be learned to the wrong location but the
first fan sensor plugged in will be assigned to Fan 1.
The first Bin Level sensor plugged in will be learned
to Bin 1, etc. The speed, pressure, and flow sensors
all use the same type sensor code so the first one
plugged in will be the speed sensor, etc.
3. Add a sensor: Individual sensors can be added to
the MuxBus system at any time. Place the highlight
bar on the sensor you want to add (Fan 2 in the
example) and press install. Then plug in the sensor.
Multiple sensors can also be added using this
method but you need to position the highlight bar
on each new sensor and press “Install” before
plugging in each sensor.
4. Remove a sensor: Individual sensors can be
removed by placing the highlight bar on the sensor
you want to remove and pressing “Remove”. Then
unplug the sensor.