beautypg.com

Seed Hawk AIRCART 2013 User Manual

Page 66

background image

SEED HAWK

®

 AIRCART OPERATOR’S MANUAL                                                                              61 

7.4.2

 ENGAGE DRIVE 


The monitor requires several pieces of information for field operation. 
 
1. There must be an Implement width entered. 
 
2. There must be a meter application rate entered. 
 
3. There must be a meter calibration rate entered. 
 
4.   Forward travel speed must be present 
 
5. The drive must be engaged. 
 
 
To engage the drive press the “ACK” button. The drive icon in the upper center portion of the 
screen  will  turn  solid.  Engaging  the  drive  will  cause  the  furrow  openers  to  lower  to  seeding 
position and with travel speed present the rate meters will begin to turn. 
 
NOTE:  you  must  have  the  fans  in  operation  before  engaging  the  drive.  If  the  fans  are  not 
operating normally, an alarm screen will show that cannot be acknowledged. 

7.4.3

 DISENGAGE DRIVE 


At  the  end  of  a  seeding  pass,  Press  the  “ACK” 
button again to disengage the meter drive. This will 
stop  the  application  rate  meters  and  raise  the 
furrow  openers.  This  will  stop  the  acre 
accumulation register as well.