8.2.2
VIPER PRO™ CALIBRATION PROCEDURE
ATTENTION: Before a meter calibration can be done the implement width must be entered
and the speed calibration must be completed (See Section Setup Wizard and Calculating the
speed Calibration sections of your Seed Hawk Viper Pro™ Manual). Exit to the Seed Hawk
Viper Pro Main Menu on the Viper monitor before powering up the Remote Calibration
Console.
NOTE: FOR CONVENIENT CALIBRATON, USE THE
REMOTE CALIBRATION CONSOLE THAT ATTACHES TO
THE TANK HARNESS.
To begin the remote calibration of the meters mount the
remote calibration console on the ram‐ball and attach the
electrical connector. Turn the console on using the blue
power button.
After turning on the remote calibration console, the bin selection screen is displayed. Using the
soft keys select the bin which corresponds to meter to be calibrated and select “ENTER”.