beautypg.com

Brocade ICX 6650 Hardware Installation Guide User Manual

Page 75

background image

Power state definitions

TABLE 14

Power state Definition

Idle

All ports down, no optics or cables connected.

Typical

56x10 GbE, 4x40 GbE, and 4x4x10 GbE ports linked and up. 10% traffic with 64-byte packets. Fans
at normal speed.

Maximum

All ports connected with optics to draw maximum power per MSA Optics Specification. Traffic at full
rate or 100% throughput. Fans at full speed.

The following table lists the power supply specifications for the AC power draw for the Brocade ICX
6650.

AC power supply system power specifications

TABLE 15

AC voltage

Input watts

BTU/hr

Power state

100-120 VAC

114.6

391.14

Idle

100-120 VAC

154.6

527.66

Typical Light Load

100-120 VAC

171.6

585.68

Typical Full Load

100-120 VAC

230

785.01

Maximum

Inrush current should be limited to a 35A peak for any initial current surge or spike of 10 ms or less at
either cold or warm start. Any additional inrush current surges or spikes in the form of AC cycles or
multiple AC cycles greater than 10 ms and less than 150 ms must not exceed a 25A peak. After 150
ms, the AC input current will be less than the rating of input fuses and the other components within the
power supply.

The following table lists the power supply specifications for the DC power draw for the Brocade ICX
6650.

DC power supply system power specifications

TABLE 16

DC voltage

Input watts

BTU/hr

Power state

40-60 VDC

114.6

391.14

Idle

40-60 VDC

154.6

527.66

Typical Light Load

40-60 VDC

171.6

585.68

Typical Full Load

40-60 VDC

230

785.01

Maximum

Brocade ICX 6650 Specifications

Brocade ICX 6650 Hardware Installation Guide

73

53-1003083-01