Environmental requirements (Continued)

TABLE 13

Condition

Acceptable during operation

Acceptable during non-operation

Shock

20 G, 6 ms, half-sine wave

33 G, 11 ms, half-sine wave, 3/eg Axis

Vibration

0.5 G sine, 0.4 gms random, 5-500 Hz

2.0 G sine, 1.1 gms random, 5-500 Hz

Airflow

Maximum - 90.1 cmh (53 cfm)Nominal - 59.5
cmh (35 cfm)

N/A

Heat dissipation

478 BTU/hr

N/A

Operating noise

46.7 dB

N/A

Cooling system and fans

The fans cool the CPU, main memory, and voltage regulators. For Brocade ICX 6650 switches, the
fans use either:

An exhaust airflow which moves air from front to back. Refer to the first figure below. Devices with
exhaust airflow are labeled with a green arrow with an “E.”

An intake airflow which moves air from back to front. Refer to the third figure below. Devices with
intake airflow are labeled with an orange arrow with an “I.”

Cooling system and fans

70

Brocade ICX 6650 Hardware Installation Guide

53-1003083-01