DIAG LED

DIAG LED

TABLE 6

LED State

Status of hardware

Recommended action

Off (no light)

Diagnostic is off.

No action required.

Blinking green System self-diagnostic test is in progress.

No action required.

Steady green

System self-diagnostic test is successfully completed. Device reboots
and clears back to off.

No action required.

Steady amber System self-diagnostic test has detected a fault.

Contact support.

Management port status LED

Management port status LED

TABLE 7

LED State

Status of hardware

Recommended action

Off (no light)

Not cabled.

No action required

Blinking

There is traffic and packets are being transmitted or received.

No action required.

Steady

No traffic being transmitted, but link is up.

No action required.

1/10 GbE SFP+ port LEDs

1/10 GbE SFP+ port LEDs

TABLE 8

LED State

Status of hardware

Recommended action

Green

Link is up in 10 GbE mode.

No action required.

Blinking green There is 10 GbE activity (traffic) and packets are being transmitted or

received.

No action required.

Amber

Link is up in 1 GbE mode.

No action required.

Blinking amber There is 1 GbE activity (traffic) and packets are being transmitted or

received.

No action required.

Brocade ICX 6650 Operation

54

Brocade ICX 6650 Hardware Installation Guide

53-1003083-01