IM 04L31A01-02E
Program Selection Display Example
Program pattern
name
Selected pattern
number
Selected segment*
number
Selected segment*
time
Segment range
to be repeated
Repeat frequency
Preset
pattern
waveform
* The selected
segment is the
segment displayed
at the left end.
Select the segment
using the left and
right arrow keys.
Display the program pattern
control start delay time
Start segment number display
Target SP display of the
selected segment*
Show the program control display
(valid only during program control)
Switches to control group display (style number S3 or later)
Switches to overview display (style number S3 or later)
Settings for pattern to be run as a result of communication function,
DI/DO, or internal switch action
Switch the program pattern
Display the window for starting the program control
Soft key menu 2/3
Display soft key menu 3/3
Display the selection menu for the event display method
(style number S3 or later)
Turns the event display ON/OFF (style number S3 or later)
Display the window for setting the program pattern control start delay time
Display the window for setting the program pattern start segment
Display the ON/OFF selection menu of program pattern display loops
Switch full display/split display
Soft key menu 3/3
Display soft key menu 1/3
Switch tag/tag comment display
Shift the displayed segment by +10 segments
Shift the displayed segment buy –10 segments
Operations on the Program Control Display (See the figure on the next page)
Displaying the Program Control Display
When you start the program control on the program selection display, the program
control display appears. You can display the program control display when program
control is in progress by selecting
CONTROL
>
PROGRAM
from the display
selection menu on the control group display or the control overview display or
pressing the
RUN PNL soft key
on the program selection display.
Executing and Clearing the Hold Operation
You can hold the progress of the program (stop the timer). While in hold, you can
change the segment SP or increase or decrease the remaining segment time.
1.
Press the
HOLD soft key
.
A pop-up window for executing/clearing the hold operation appears.
Window for executing/
clearing the hold operation.
2.
Select [ON] (execute) or [OFF] (clear) using the
up and down arrow keys
.
3.
Press the
DISP/ENTER key
.
Program Control Function (/PG1 and /PG2 Options)