Menu overview, A.10 menu overview, A.10 – Watlow Series 988 User Manual

Page 150: Operation menus display loop, Setup menus factory menus, Watlow series 988 user’s manual appendix

background image

Fcty

Factory

( )

A.10

WATLOW Series 988 User’s Manual

Appendix

(SyS)

Alarm 2 low

Event input 2 status

Alarm 2 high

Alarm 3 low

Alarm 3 high

(System)

Event input 1 status

Ei1S

A2LO

A2HI

A3LO

A3HI

Ei2S

A4LO

AUt

L-r

A4HI

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

Auto-tune

Alarm 4 high

Local-remote

Alarm 4 low

(PIDA)

Output 1 integral A

Output 1 reset A

Output 1 rate A

Output 1 derivative A

Output 1 cycle time A

(PIDA)

Output 1 proportional band A

Pb1A

It1A

rA1A

dE1A

Ct1A

rE1A

Pb2A

It2A

rA2A

rE2A

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

Output 2 integral A

Output 2 reset A

Output 2 rate A

Output 2 proportional band A

Ct2A

db A

dE2A ( )

( )

( )

Output 2 cycle time A

Output 2 derivative A

Dead band A

(PIDB)

Output 1 integral B

Output 1 reset B

Output 1 rate B

Output 1 derivative B

Output 1 cycle time B

(PIDB)

Output 1 proportional band B

Pb1b

It1b

rA1b

dE1b

Ct1b

rE1b

Pb2b

It2b

rA2b

rE2b

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

Output 2 integral B

Output 2 reset B

Output 2 rate B

Output 2 proportional band B

Ct2b

db b

dE2b

( )

( )

( )

Output 2 cycle time B

Output 2 derivative B

Dead band B

SP2

IdSP

Set point 2

Idle set point

( )

( )

Operation

OPEr ( )

At the

[`SEt] prompt, press > and < another

3 seconds to enter the Factory menus.

Press > and < for 3 seconds to enter
the Setup menus. Outputs are disabled.

Figure A.10 -
The Series 988 Map.

75

50

°F

0

% OUT LED on

DEV LED on

Process units

Process input 2

Pr 2

Set point 1,

Remote

set point or
Ratio value

Inner Loop

set point

(cascade only)

InSP

(InPt)

Range high 1

Range low 1

Calibration offset 1

Decimal place 1

(Input)

Input 1

In1

rH1

CAL1

dEC1

rL1

Lin1

rSP

rL2

rH2

CAL2

In2

rtd2

Ftr2

Lin2

Hunt

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

Remote set point

Input 2

Range low 2

Range high 2

Calibration offset 2

Input 1 linearization

RTD calibration curve 2

Input 2 software filter

Input 2 linearization

Slidewire dead band

dEC2

Decimal place 2

Input 1 software filter

Ftr1

RTD calibration curve 1

rtd1

( )

( )

( )

( )

LrnL

LrnH

Learn range low

Learn range high

SHyS ( )

Slidewire inner
hysteresis

Retransmit low limit

Retransmit high limit

Retransmit cal. offset

(OtPt)

Hysteresis 1

Process 1

Output 2

Process 2

Hysteresis 2

(Output)

Output 1

Ot1

HYS1

Ot2

Prc2

HYS2

Prc1

SP2c

LAt2

SIL2

A3Sd

HYS3

AL2

LAt3

SIL3

A4Sd

HYS4

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

Latching for alarm 2

Alarm 2

Silence alarm 2

Alarm 3 side

Hysteresis 3

Control set point 2

Latching for alarm 3

Silence alarm 3

Alarm 4 side

Hysteresis 4

LAt4

SIL4

Aout

A r L

A r H

( )

( )

( )

( )

( )

Latching for alarm 4

Silence alarm 4

Analog output

ACAL

Ot3

Ot4

( )

( )

( )

Output 3

Output 4

( )

Prc3

Process 3

AL4

( )

Alarm 4

AL3

Alarm 3

( )

A2Sd ( )

Alarm 2 side

(COM)

Protocol type

Data bits and parity

Address

Interface type

(Communications)

Baud rate

bAUd

Prot

Addr

intF

dAtA

( )

( )

( )

( )

( )

(gLbL)

Failure mode

Error latching

Control type

(Global)

Celcius_Fahrenheit

C_F

FAIL

Err

CntL

CSAC

Proc

StPt

Ei1

Pid2

Ei2

Anun

HiP

AtSP

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

Crossover process value

PID 2 crossover selection

Crossover set point value

Event input 1

Cascade action

Event input 2

Annunciator

High power limit

Auto-tune set point

rP

rAtE

( )

Ramping function

Ramp rate

LoP

( )

( )

Low power limit

ALgO ( ) Control algorithm

(PLOC)

PIDA menu lockout

System menu lockout

PIDB menu lockout

Input menu lockout

Output menu lockout

(Panel Lockout)

Front Panel lockout

Diagnostics menu lockout

Communications menu lockout

Global menu lockout

Calibration menu lockout

LOC

PidA

Pidb

InPt

OtPt

SyS

gLbL

COM

diAg

( )

( )

( )

( )

( )

( )

( )

( )

( )

CAL

( )

Test output

(diAg)

Software revision

Serial number

Ambient temperature

Ambient A/D count

(Diagnostics)

Factory ship date

dAtE

SOFt

Sn

AMb

Acnt

gnd

cnt2

ity1

ity2

cnt1

Oty1

Oty2

Oty4

dISP

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

Input 2 A/D count

Input 1 A/D count

Input 1 module

Input 2 module

Ground A/D count

Output 1 module

Output 2 module

Output 4 module

Test displays

tout

( )

Oty3

( )

( )

Output 3 module

Open loop

OPLP ( )

(CAL)

(Calibration)

A 50

tc

A 0H

A 20

A 15

A 00

A380

A 0u

A20A

b 15

b380

A10U

b10U

b 0U

b 4A

b 0u

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

b100

1 4

1 20

1 0

1 10

2 4

A 4A

b20A

Default prompts

2 20

2 0

2 10

3 LO

3 HI

rSt

dFL

A 0u

A100

b 00

b 0H

b 50

( )

( )

( )

( )

( )

( )

b 20

Restore factory values

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

( )

Setup

SEt

( )

˜

NOTE:
This is a complete
listing of all Series
988 prompts.

Not all prompts will
appear on your con-
trol. They are
dependent on your
configuration and
model number.

Operation Menus

Display Loop

(Lower Display)

Setup Menus

Factory Menus

To navigate:

Press ¥ to return
to the Display Loop
from any location and
to advance through
the Display Loop.

Press > or < to
move between the
menus.

Press µ to
advance through a
menu.

Hold µ while
pressing > to
move backwards
through the menus.

Press > or < to
select prompt values.

Press µ to advance to the Operation
menus. Outputs are still active.

Press ¥ to exit
any menu and
reach the Display
Loop at any time.

Menu Overview

µ

µ

µ

µ

µ

µ

µ

µ

µ

µ

>

>

>

NOTE:
The controller will
not default back to
normal display
while in the Factory
Menu. All outputs
are disabled while
in this menu.