Factory Menus, Chapter 6

6.14

WATLOW Series 988 User’s Manual

Restore

Restores the original factory calibration values when set to

[[`

`Y

YE

ES

S]].

This is a simple way to recover from a mistake made while calibrating the
controller.

[`rSt] This prompt always appears.

Default

[``no]

[`yes]

[`rSt]

[`rSt]

Default

Set the operating parameter defaults to domestic or international
measures.

[``US] (domestic) sets the controller to °F; rate in minutes; proportional
band in degrees or units; and reset in repeats per minute.

[``SI] (international) sets the controller to °C; derivative in minutes;
proportional band in percent of span; and integral in minutes per repeat.

[`dFL] This prompt always appears.

Default

[``US]

[``sI]

[`dFL]

[`dFL]

[`rst]

Factory-Calibration

[`dfl]