beautypg.com

1 description, 1 description -35 – Watlow 12LS Controller User Manual

Page 68

background image

4-35

4.6.1 DESCRIPTION

A ramp / soak profile consists of several groups of parameters: those global to the profile as a unit,
those defined as the "ready state" for the profile, and those specified for each segment of the
profile.

The "ready state" is assigned as segment 0, although it is not an executable segment.

The remaining executable segments each comprise one time period within the profile in which
either a change of setpoints occurs or a single setpoint is held.
|-------------------------------------------------------------|
¦ PARAMETERS GLOBAL TO EACH PROFILE ¦
|-------------------------------------------------------------¦
¦ Tolerance Time ¦ Maximum allowable time out of tolerance ¦
¦ ¦ within any single segment. Timer reset ¦
¦ ¦ at beginning of each new segment. ¦
|-------------------¦-----------------------------------------¦
¦ Last Segment ¦ Specifies which segment is the final ¦
¦ ¦ segment of the profile. ¦
|-------------------¦-----------------------------------------¦
¦ Cycles ¦ Number of times a profile is to be ¦
¦ ¦ repeated. Can be set from 1 to 99 or as ¦
¦ ¦ continuous. ¦
|-------------------------------------------------------------|
|-------------------------------------------------------------|
¦ PARAMETERS SPECIFIC TO THE READY STATE ¦
|-------------------------------------------------------------¦
¦ Ready Setpoint ¦ Setpoint to be loaded before a profile ¦
¦ ¦ begins running, after a profile ends ¦
¦ ¦ or when a profile is aborted. ¦
|-------------------¦-----------------------------------------¦
¦ Ready Event States¦ The outputs to be activated prior to ¦
¦ ¦ beginning execution of the first segment¦
¦ ¦ of a profile. The default is all outputs¦
¦ ¦ off. ¦
|-------------------------------------------------------------|