Proface APL3000B - Node Box PC User Manual
Page 107

PS-3650A / PS-3651A User Manual
6-6
• General-Purpose Input (DIN) level must be 1.5 seconds or longer to be detected.
It may not detect under 1.5 seconds.
• Be sure the voltage value between terminals is controlled via the input voltage, so
that the PS-A is operated within its recommended range. If the input voltage
exceeds this range, a malfunction or PS-A damage may occur.
• With Sink/Source input, even if the D(-), and RESET(-) are positive, and D(+),
RESET(+) are negative, no problems are created. Be sure to operate the unit within
the recommended voltage range.
•
For connection pin location details,
DC12 to 24V
DIN 0(+)
DIN 1(+)
+
+
-
-
Vcc
Vcc
PC357
R
R
R
R
DINCOM
Internal circuit
Input part circuit
No polar character
for sink source input
(Interface circuit)
Input port
Input port
SEE