beautypg.com

10 2-ch analog-output module – Proface AGP3500 - 10.4 DIO HMI" User Manual

Page 33

background image

33

‹ Wiring

indicates a fuse.

• The power for the analog module should be supplied separately from the LT.

Turn the analog module on before turning the LT on. Wait at least 30 seconds
after power-off to restart the external power-supply or it may not operate properly.

• Be sure the analog OUT lines are placed in a separate duct from high-frequency,

live lines such as high-voltage, high-power lines, inverters, etc.

• Connect a fuse appropriate for the applied voltage and current draw, at the position shown

in the diagram.

• Do not connect any wiring to unused channels.

15.10 2-ch analog-output module

The detail of the external power supply is: the rated supply voltage is 24 VDC, the rated input
voltage ranges from DC19.2 to 30 V including ripple. The consumption current is 60 mA
(24 VDC) when the input is not-open, output 100%.

EXM-AVO2HT

Analog Output Specifications

Voltage Output

Rated Output Voltage Range

From DC -10 to +10 V

Load

Load Impedance

3 k

Ω min.

Application Load Type

Resistive load

D-A
Conversion

Conversion Time

2 ms

Total Output System
Transfer Time*

1

2 ms + 1 scan time

- +

+

-

+

-

OUT

+

-

Analog voltage/
current input
device

24 VDC

24
VDC