beautypg.com

Clear, Delete, Delta+/delta – Maple Systems OIT Family (ASCII) User Manual

Page 52: Enter, Help, Last message/next message, Page up/page down, Setup, Toggle

background image

Clear

The Clear key performs three functions. If an alarm is active, pressing the Clear key turns off

the buzzer. In local setup mode, pressing the Clear key will back out of the menus and even-

tually exit local setup mode without saving any of the changes. When a read/write register

monitor is on the screen, pressing the Clear key clears the current register monitor’s contents

and activates data entry mode. The register monitor field becomes blank and the cursor is po-

sitioned in the rightmost character position.

Delete

The Delete key performs a destructive backspace at the cursors current position in the screen.

Delta+/Delta-

Each read/write register monitor can be configured to use the increment/decrement keys.

These keys can be enabled/disabled and configured with a particular step value for each

read/write register monitor. Each time the OIT operator presses one of these keys, the value in

the OIT data register is changed by adding/subtracting the step value. As each key is pressed,

the OIT data register is updated immediately and will be visible on the display as it occurs.

Enter

The Enter key performs two functions. In local setup mode, pressing the Enter key accepts

the current entry and advances to the next menu. When a read/write register monitor is on the

screen, pressing the Enter key accepts the data entered by the OIT operator and updates the

OIT data or coil register.

Help

The Help key displays the help screen attached to the message, recipe, or menu screen cur-

rently being displayed.

Last Message/Next Message

The Last Message and Next Message keys allow the OIT operator to review the screens that

were previously displayed on the OIT and then return to the most recent screen. In Stacked

Mode, the Next Message key causes the next message in the message stack to be displayed.

Page Up/Page Down

The Page Up and Page Down keys allow the OIT operator to move through a group of

chained screens.

Setup

The Setup key places the OIT into setup mode. On the OIT3160 and OIT4160 setup mode is

entered by holding down the Clear key when the OIT is being powered up or pressing Enter

three times during operation.

Toggle

The Toggle key performs two functions. In local setup mode, pressing the Toggle key will ad-

vance through the various selections for the current menu. When a binary read/write register

monitor is on the screen, pressing the Toggle key changes between the two binary values.

FEATURES

51

1010-0088, REV02