Full Mode

Fan is on all the time

Manual PWM Mode

The fan spins at the speed set in the

manual PWM setting

Auto PWM Mode

D

EFAULT

The fan adjusts its speed using these

settings:

Temperature of Start

Temperature of Off

Start PWM

Slope (Duty Cycle)

 Tem p eratu re o f Off [75]

WARNING:

Setting this value too high may cause the fan to speed up only when

the CPU is at a very high temperature and therefore cause the system

to be damaged.

The Temperature of Off option can only be set if the CPU Smart Fan control option is

set to Auto Mode. When the CPU Temperature is lower than Temperature of Off, the

fan speed change to be lowest. To set a value, select the Temperature of Off option and

enter a decimal number between 0 and 127. The temperature range is specified below.

 Minimum Value: 0°C

 Maximum Value: 127°C

 Tem p eratu re o f Start [80]

WARNING:

Setting this value too high may cause the fan to rotate at full speed only

when the CPU is at a very high temperature and therefore cause the