Maintenance inspection, 1 inspection items and inspection schedule, 2 visual inspection – IAI America IF User Manual
Page 47: 3 cleaning, 5㧚 maintenance inspection
5. Maintenance inspection
41
5㧚 Maintenance inspection
5.1 Inspection Items and Inspection Schedule
Have maintenance inspections following the intervals below.
8 hours per day is assumed as operation condition
Have inspections more frequently if the operation frequency is high for night and day continuous
operation, etc.
Visual inspection
Internal Check
Grease supply
*1
At startup
inspection
{
1 month after start
of operation
{
6 months after start
of operation
{
{
1 year after start of
operation
{
{
{
Every 6 months
thereafter
{
Every year
thereafter
{
{
{
*1 If the actuator is operated back and forth repeatedly over a distance of 30 mm or less, the oil film created
by the grease may be broken. It is recommended to have 5 cycles of back and forth operation in a distance
more than 50mm after every 5,000 to 10,000 rounds of the short distance operation. A layer of the grease
will recover.
5.2 Visual inspection
Conduct he item below in the visual inspection.
Main Body
Looseness of attachment screws
Cables
Scratches, proper connection of
connectors
Overall
Vibration, Abnormal noise
5.3 Cleaning
x
Please clean the external body on a regular basis.
x
When cleaning, wipe with a soft cloth to remove dust and dirt.
x
Do not blow compressed air so dust would not get in from gaps.
x
Do not apply petroleum solvent since it may damage the resin or painted surfaces.
x
When extremely dirty, wipe it off firmly with cloth that a neutral detergent or alcohol is applied
on.