Piece count and total – Fairbanks FB2255 Series Instrument PC2255 PC Software Utility Program User Manual
Page 20

Section 3: Serial Communication Wiring
01/13
20
51297 Rev. 1
2.13. Piece Count and Total
This feature enables the FB2255 to count and display the Net Weight of the counted
items, and to display the total amount of those items.
1. Place the container on the scale platform.
2. Press
TARE
to calculate the container weight.
3. The Display should indicate
0 NET WEIGHT
.
4. Press the
B/G NET
key.
5. When the display prompts to "Add", add a number of sample parts to the
Container.
6. Press
B/G NET
repeatedly until the display reads to; "Add 1", "Add 5", "Add
10", "Add 25", Add 50", or "Add 100" parts.
7. Add the required sample to the container.
– The Display will alternate between the Weight and Number of Pieces,
including the original sample.
8. Add the remaining parts to the container.
– The Display will update and continue to alternate between the Weight and
Number of Pieces, including the original sample.
9. Press
B/G NET
.
– The Display will alternate between the "Total" legend and the Total Number
of Pieces Accumulated.
10. Press
UNITS
to return to the Weigh Mode.
NOTE:
If the prompts do not occur, clear the
ACCUMULATOR
and start over.
The Operating Mode must be set to
Piece Count & Total
to function.
To reset Piece Count – see “CLEARING THE ACCUMULATOR”.