beautypg.com

Piece counting, Tare, B/g net – Fairbanks FB2255 Series Instrument PC2255 PC Software Utility Program User Manual

Page 19: Units, Accumulator, Piece count & total

background image

Section 3: Serial Communication Wiring

01/13

19

51297 Rev. 1

Place

Container

on Scale

Press

TARE

Tare stored.

Press

B/G

Select sample

size

. Scale in

NET

MODE

Add sample.

Press

UNITS

Add remaining

parts

Press

B/G NET

to Exit

2.12. Piece Counting

5. Place the empty weighing container on the Scale Platform.

6. Press

TARE.

– This stores the container weight the only, placing the scale

in the Net Mode.

“0 Net Weight” should display on the indicator.

7. Press

B/G NET

.

– The Display prompts to "Add" a number of sample parts to

the container.

8. Pressing the

B/G NET

key repeatedly prompt the user to;

"Add 1", "Add 5", "Add 10", "Add 25", Add 50", or "Add 100"
parts.

9. Add the required sample to the container, then press

UNITS

.

– The Display alternates between indicating the weight and

the number of pieces.

10. Add the remaining parts to the container.

– The display will update and continue to alternate between

the Weight and Number of Pieces, including the original
sample.

11. Press

B/G NET

.

– Pressing the

B/G NET

key will skip adding the Current

Piece to the Total Register and return to the Weigh Mode.

See the Print Example below.

NOTES:

If the prompts do not occur, clear the

Accumulator

and start over.

The operating mode must be set to

PIECE COUNT & TOTAL

to function.