Piece counting, Tare, B/g net – Fairbanks FB2255 Series Instrument PC2255 PC Software Utility Program User Manual
Page 19: Units, Accumulator, Piece count & total
Section 3: Serial Communication Wiring
01/13
19
51297 Rev. 1
Place
Container
on Scale
Press
TARE
Tare stored.
Press
B/G
Select sample
size
. Scale in
NET
MODE
Add sample.
Press
UNITS
Add remaining
parts
Press
B/G NET
to Exit
2.12. Piece Counting
5. Place the empty weighing container on the Scale Platform.
6. Press
TARE.
– This stores the container weight the only, placing the scale
in the Net Mode.
– “0 Net Weight” should display on the indicator.
7. Press
B/G NET
.
– The Display prompts to "Add" a number of sample parts to
the container.
8. Pressing the
B/G NET
key repeatedly prompt the user to;
"Add 1", "Add 5", "Add 10", "Add 25", Add 50", or "Add 100"
parts.
9. Add the required sample to the container, then press
UNITS
.
– The Display alternates between indicating the weight and
the number of pieces.
10. Add the remaining parts to the container.
– The display will update and continue to alternate between
the Weight and Number of Pieces, including the original
sample.
11. Press
B/G NET
.
– Pressing the
B/G NET
key will skip adding the Current
Piece to the Total Register and return to the Weigh Mode.
See the Print Example below.
NOTES:
If the prompts do not occur, clear the
Accumulator
and start over.
The operating mode must be set to
PIECE COUNT & TOTAL
to function.