Section 5: Programming Configuration

04/13

50

51278 Rev. 2

E. Filter

The digital filter will assist in minimizing undesirable effects of elements such as
vibration and air movement upon the scale weighing pan.

Display

Descriptions

FLtr 2

Filter set to 2 A/D updates a second.
Light filtering

FLtr 4

Filter set to 4 A/D updates a second. (Default)
Light – Medium filtering

FLtr 8

Filter set to 8 A/D updates a second.
Medium filtering

FLtr 16

Filter set to 16 A/D updates a second.
Medium-Heavy filtering

FLtr 32

Filter set to 32 A/D updates a second.
Heavy filtering

F. Sample Piece Default
This setting allows the default sample size to be changed.

Display

Descriptions

SAndEF 10 Sets the default sample size to 10 pieces.

SAndEF 25 Sets the default sample size to 50 pieces.

SAndEF 50 Sets the default sample size to 50 pieces.

SAndEF 100 Sets the default sample size to 100 pieces. (Factory Default)