Fairbanks OMEGA SERIES COUNTING SCALE User Manual
Page 25

Section 4: User Operations
04/13
25
51278 Rev. 2
4.7.1. ACCUMULATION, CONTINUED
Example:
1. Clear scale weighing pan. Make sure the weight is 0. If weight is not 0, use
zero key to reset.
2. Press
key to set Piece Weight as 0.5 pounds.
3. Put 1 pound item on scale weighing pan and waiting for stable.
4. Press
key. After on beep sound,
lights up.
5. Remove item on scale weighing pan. Make sure the weight is 0 again.
6. Press
key to set Piece Weight as 0.1 pounds.
7. Put 2 pounds item on scale weighing pan and waiting for stable.
8. Press
key. After on beep sound,
lights up.
Note:
After each recording, if the load on the weighing pan is not cleared, pressing
will
result in a long beep and the scale will not be able to record the next weighing result.
Note:
The stored memory can memorize up to 180 weighing results.
4.7.2. RECALL
A. Total mode
1. In weighing mode, press
and the Weight column will be cleared. The
Piece Weight column displays
.
2. The PCS column shows the total piece count in memory. The Weight
column shows the accumulated weight.
3. The number above “ACC” indicator is the record size.
4. Press
to exit without clearing the data.
5. Press
to clear the data and exit.