beautypg.com

Fairbanks OMEGA SERIES COUNTING SCALE User Manual

Page 25

background image

Section 4: User Operations

04/13

25

51278 Rev. 2

4.7.1. ACCUMULATION, CONTINUED

Example:
1. Clear scale weighing pan. Make sure the weight is 0. If weight is not 0, use

zero key to reset.

2. Press

key to set Piece Weight as 0.5 pounds.

3. Put 1 pound item on scale weighing pan and waiting for stable.

4. Press

key. After on beep sound,

lights up.

5. Remove item on scale weighing pan. Make sure the weight is 0 again.

6. Press

key to set Piece Weight as 0.1 pounds.

7. Put 2 pounds item on scale weighing pan and waiting for stable.

8. Press

key. After on beep sound,

lights up.

Note:

After each recording, if the load on the weighing pan is not cleared, pressing

will

result in a long beep and the scale will not be able to record the next weighing result.

Note:

The stored memory can memorize up to 180 weighing results.

4.7.2. RECALL

A. Total mode

1. In weighing mode, press

and the Weight column will be cleared. The

Piece Weight column displays

.

2. The PCS column shows the total piece count in memory. The Weight

column shows the accumulated weight.

3. The number above “ACC” indicator is the record size.

4. Press

to exit without clearing the data.

5. Press

to clear the data and exit.