Fairbanks OMEGA SERIES COUNTING SCALE User Manual
Page 44

Section 5: Programming Configuration
04/13
44
51278 Rev. 2
Example 2:
1. Open a hyper terminal session and connect at 9600 8-n-1.
2. Set Serial 1 to PrESS, weight output using print net. Set the baud rate to
9600, 8 characters, No parity, and 1 stop bit.
3. Set PLU = no, Time and date = YES, Piece information = no, Piece Weight
= YES, Accumulation information = YES, and Accumulation Weight =
YES.
4. Press
to set Piece Weight as 0.001 lb.
5. Press
to store the current data in PLU 1.
6. Place a 1 pound item on scale weighing pan.
7. Press
to record 1 Accumulation data.
8. Press the
key. The data output is shown below:
1.0000 lb NT
0.001 lb PW
1.0000 lb NT ACC
05:40 PM
01/01/2010
Example 3:
1. Open a hyper terminal session and connect at 9600 8-n-1.
2. Set Serial 1 to PrESS, weight output using print net. Set the baud rate to
9600, 8 characters, No parity, and 1 stop bit.
3. Set PLU = Yes, Time and date = YES, Piece information = no, Piece
Weight = YES, Accumulation information = no, and Accumulation Weight
= no.
4. Press
to set Piece Weight as 0.001 lb.
5. Press
to store current data in PLU 1.
6. Place a 1 pound item on scale weighing pan.
7. Press
to record 1 Accumulation data.
8. Press the
key. The data output is shown below:
PLU 1
1000 PCS
0.001 lb PW
05:43 PM
01/01/2010