beautypg.com

Fairbanks OMEGA SERIES COUNTING SCALE User Manual

Page 43

background image

Section 5: Programming Configuration

04/13

43

51278 Rev. 2

12. Serial 1 - Accumulation Weight Information Print

Display

Descriptions

SEr.1
ACC.LUGt
no

Data prints without the total accumulated weight. (Default)

SEr.1
ACC.LUGt
YES

Data prints with the total accumulated weight.

Example 1:

1. Open a hyper terminal session and connect at 9600 8-n-1.

2. Set Serial 1 to PrESS, weight output using print net. Set the baud rate to

9600, 8 characters, No parity, and 1 stop bit.

3. Set PLU = YES, Time and date = no, Piece information = YES, Piece

Weight = no, Accumulation information = YES, and Accumulation Weight

= no.

4. Press

to set Piece Weight as 0.001 lb.

5. Press

to store current data in PLU 1.

6. Put 1 pound item on scale weighing pan.

7. Press

to record 1 Accumulation data.

8. Press the

key. The data output is shown below:

1.0000 lb NT

PLU 1

1000 PCS

1 ACC#