Fairbanks OMEGA SERIES COUNTING SCALE User Manual
Page 29
Section 4: User Operations
04/13
29
51278 Rev. 2
B. Weight alarm
1. After the Piece alarm is configured, the scale will enter the Weight alarm
setting.
2. The PCS column displays
. Set up the Weight Lower Limit
with the numeric keys. (If the unit is kg, this unit is in grams. If the unit is
lb, this unit is in lb)
3. Press
key again, the PCS column displays
. Set up the
Weight Lower Limit with the numeric keys. (If the unit is kg, this unit is in
grams. If the unit is lb, this unit is in lb)
4. Press
key to save your settings and return to weighing mode.
Example:
1. Press
key three times to enter Weight Upper Limit setting. The PCS
column displays
2. Input 10 to set Weight Upper Limit as 10.
3. Press
key to enter Weight Lower Limit setting. The PCS column displays
4. Input 1 to set Weight Upper Limit as 2.
5. Press
to complete Weight alarm setting.
6. Put 1 pound on scale weighing pan. The Lower Limit alarm is indicated.
(Lower Limit indicator begins flashing. If the Low Beep sound is enabled, it
will sound an audile alarm.)
7. Put 11 pounds on scale weighing pan. Upper Limit alarm is indicated. (Upper
Limit indicator begins flashing. If the High Beep sound is enabled, it will
sound an audible alarm.)
Note:
1. If the piece count exceeds the upper limit of PCS Upper Limit, or lower than the
PCS Lower Limit and it is not zero, the scale will continue to beep for a warning.
2. If the weight exceeds the upper limit of Weight Upper Limit, or lower than the
Weight Lower Limit and is not zero, the scale will continue to beep for a warning.
3. The beep settings are configured in he SEtUP menu.