beautypg.com

Fairbanks OMEGA SERIES COUNTING SCALE User Manual

Page 40

background image

Section 5: Programming Configuration

04/13

40

51278 Rev. 2

4. Serial 1 - Parity continued,

Display

Descriptions

SEr.1

PArit

8-E-1

Sets the parity to 8-E-1

SEr.1

PArit

8-o-1

Sets the parity to 8-o-1

SEr.1

PArit

7-o-2

Sets the parity to 7-o-2

Example:

To print net weight only:

1. Open a hyper terminal session and set connection as 9600 8-n-1.

2. Set Serial 1 as PrESS, weight output as print net, baud rate as 9600 and

parity as 8-n-1, and others parameters are set to No.

3. After the scale boot, press the

key. Data on Hyper terminal will show:

0.0000 lb NT

4. Cycle power to the scale and change serial 1 settings to Auto. Change the

weight output to print Gross, Tare and Net. Change the baud rate to 19200

and parity as 7-n-2 , and all others parameters are set to No.

5. Close hyper terminal and modify its connection as 19200 7-n-2.

6. After the scale reboot, put 1 pound item on scale pan.

7. The scale will output data when the weight is stable. The Data output will be

as show below:

1.0000 lb GR

0.0000 lb TA

1.0000 lb NT