Print settings (prt) – Fairbanks OMEGA SERIES COUNTING SCALE User Manual
Page 38

Section 5: Programming Configuration
04/13
38
51278 Rev. 2
5.5. PRINT SETTINGS (PRT)
Press
to toggle among the options, and press
to confirm.
1. Serial 1 - Output Method Changes the method to initiate data information
output.
Display
Descriptions
SEr.1
PrESS
Initiates data transmission when the PRINT key is pressed
.
(Default)
SEr.1
Auto
Initiates data transmission when scale weight is stable.
Scale weight must return to zero before the next print will
occur.
SEr.1
rEn.dS
Remote display Output. This programs the serial 1 output
as fixed remote display output which is configured using
19200 as baud rate, 8 characters, No parity, and 1 stop bit.
These settings cannot be changed.
SEr.1
Poll
Initiates data transmission when a
2. Serial 1 - Weight Output Change the weight output data of serial 1. Print
net only or print Gross, Tare, and Net.
Display
Descriptions
SEr.1
Pr.nEt
nEt
Outputs only the Net weight.
SEr.1
Pr.nEt
G.t.nEt
Outputs Gross, Tare, and Net weights. (Default)
- 6001 Delta Series Analog Platforms (20 pages)
- NexWeigh (80 pages)
- 5001 Series QuickSilver IS (25 pages)
- 5000 Series Bench Scale Platforms (22 pages)
- Series II Bench Scales (14 pages)
- Series III Bench Scales (15 pages)
- SCB-R9000-B Series Ultegra Baggage (19 pages)
- SCB-R9000-14U Ultegra Bench Scale (16 pages)
- SCB-R9050 Series Ultegra MAX (17 pages)
- Ultegra Junior Bench Scale (18 pages)
- 1129 SERIES Dual Platform Counting Scale (50 pages)
- AN Series Fairbanks Access Solutions (120 pages)
- FB2550 DAT SERIES DRIVER ACCESS TERMINAL (159 pages)
- Aegis Xtreme-Duty Floor Scale (32 pages)
- Aegis Transport Scale (32 pages)
- Aegis Lift Deck (26 pages)
- Aegis Industrial Mild Steel (30 pages)
- Aegis Heavy Capacity PLF-6200-H Series (18 pages)
- Aegis Drum Scales (34 pages)
- Aegis Coil Scales (42 pages)
- BlueLineFS Scale System (24 pages)
- 3300 Reliant Series Floor Scale (19 pages)
- 3500 Series Yellow Jacket (26 pages)
- FB1100 Series Yellow Jacket FS Package (30047, 30048) (70 pages)
- FB2250 Series Yellow Jacket FS Package (94 pages)
- IM 6000 Series In-Motion Scale System with FB3000 (25 pages)
- Ultegra Health Scale (10 pages)
- 27135 TeleWeigh with Bluetooth (18 pages)
- 26889 Slimline Health Scale (16 pages)
- BPP1000 Portable Platform Scale (22 pages)
- 1155 SERIES Portable Utility SCALE WITH THE FB2255 (32 pages)
- 1124 Portable Platform Scale (16 pages)
- 1100 Series Portable Utility Scale with Rechargeable battery-powered FB1100 ABS (22 pages)
- H90-5200-A Digital Instrument (60 pages)
- FB2255 Series Instrument PC2255 PC Software Utility Program (79 pages)
- FB3000 Highway System Application (96 pages)
- FB2550 SERIES (186 pages)
- FB6001 INSTRUMENTATION (83 pages)
- FB3000 II Operators Manual (68 pages)
- FB3000 Inbound/Outbound Program Operators Manual (40 pages)
- FB3000 Kernel Program Operators Manual (69 pages)
- H90-3052-D Fairbanks Scales (19 pages)
- 2800 Series Intrinsically Safe Instrument (73 pages)
- 12-1492 - 12-1496 A.A.R. Combination Railroad Track/MTS (59 pages)