Fairbanks OMEGA SERIES COUNTING SCALE User Manual
Page 35

Section 5: Programming Configuration
04/13
35
51278 Rev. 2
6. bEEP – Audible Keystroke Setting
Display
Descriptions
bEEP no
Turns the keystroke audible beep off
bEEP YES
Turns the keystroke audible beep on. (Default)
Example:
1. Set bEEP = no.
2. Press the enter key, The scale will confirm without any sound.
3. Power cycle OCS and enter setting again. Set bEEP = YES.
4. Press the ENTER key, The scale will emit a short beep.
7. A.SLUtC – Auto Switching Setting (Scale A/B)
Display
Descriptions
A.SLUtC no While sampling, do not switch from external scale to main scale.
A.SLUtC YES
While sampling, switch from external scale to main scale.
(Default)
Example:
1. Set A.SLUtC =YES. External scale must be calibrated before this is
performed.
2. Press
to switch to external scale. The scale indicator will switch to the B
scale.
3. Press
key to do sample process. The scale will switch to the Main Scale
and wait for a stable weight. Do not put the sampling item on the scale right
now.
4. After Main Scale has a stable weight and the ‘SANPLE’ is blinking on the
second row of the display, input on the desired sample count and place the
sample items on Main Scale pan. Wait for a stable weight again, and the
sampling operation is done.
5. After the Sampling operation complete, the scale will switch back to the
external scale.
6. Cycle power to the scale and enter to the A.SLUtC setting. Set A.SLUtC = no.
7. When the scale is ready, press
to switch to the external scale.
8. Press
key to perform a sample process. The scale will perform a
Sampling operation with the external scale.