beautypg.com

Fairbanks OMEGA SERIES COUNTING SCALE User Manual

Page 20

background image

Section 4: User Operations

04/13

20

51278 Rev. 2

Note:

If weighing is performed on external scale, after the

is pressed, the sampling job

will be continued on main scale automatically when auto switch is configured in the
scale counting parameter setting.

4.5.5. SETUP PIECE WEIGHT BY SAMPLING (RE-SAMPLE)

If the piece weight and weight has not been cleared, you may add or remove weight

and press

to calculate the piece weight again.

Example

1. Place 1 lb on the scale weighing pan.

2. Press

to set the item number as 5. It is displayed on the second line.

3. Press

and to display the piece weight on the second line and the piece

count on the third line.

4. Press

again to use piece count number 5 to sample again.

4.5.6. AUTO RE-SAMPLE OPERATION

After a successful sampling operation, the scale will automatically sample again on
the main scale for any new small weight. Placing new weight onto the scale weighing
pan will automatically sample again.

Example

1. Press

to into sample mode.

2. Press

to set item number as 50. It is displayed on the third line.

3. Place 5 lb item on scale weighing pan.

4. Wait for 5 seconds until the weight stable. The piece weight displays 0.1 and

piece count displays 50.

5. Place 1 lb item on scale pan.

6. Upon a stable weight, the scale will re-sample.

Note:

The new small weight should be less than half of the sampling weight. The item
change must be greater than 5. If the weight change is larger than half of the
sampling weight, auto re-sample will stop.