Note:
If weighing is performed on external scale, after the
is pressed, the sampling job
will be continued on main scale automatically when auto switch is configured in the
scale counting parameter setting.
4.5.5. SETUP PIECE WEIGHT BY SAMPLING (RE-SAMPLE)
If the piece weight and weight has not been cleared, you may add or remove weight
and press
to calculate the piece weight again.
Example:
:
:
:
1. Place 1 lb on the scale weighing pan.
2. Press
to set the item number as 5. It is displayed on the second line.
3. Press
and to display the piece weight on the second line and the piece
count on the third line.
4. Press
again to use piece count number 5 to sample again.
4.5.6. AUTO RE-SAMPLE OPERATION
After a successful sampling operation, the scale will automatically sample again on
the main scale for any new small weight. Placing new weight onto the scale weighing
pan will automatically sample again.
Example:
:
:
:
1. Press
to into sample mode.
2. Press
to set item number as 50. It is displayed on the third line.
3. Place 5 lb item on scale weighing pan.
4. Wait for 5 seconds until the weight stable. The piece weight displays 0.1 and
piece count displays 50.
5. Place 1 lb item on scale pan.
6. Upon a stable weight, the scale will re-sample.
Note:
The new small weight should be less than half of the sampling weight. The item
change must be greater than 5. If the weight change is larger than half of the
sampling weight, auto re-sample will stop.