Installation and Maintenance Manual

23

D0119, Rev. F

Smart Touch Installer Menu Functions


The Installer Menu can be accessed only by entering the User Menu first, and then by pressing the Reset
button and the Open button

simultaneously (some older software requires the Reset button be pressed first

and held while the Open button is pressed).

To restore the factory default settings, go to menu item [Fd_0] and change the setting to 1, then press
the Program Menu button. The entire menu will reset to the factory defaults.

Installer Menu Options Default

Description

I1

[uC 0] Set UL Usage Class

0

0 = gate disabled, Set Class 1 through 4 use

I2

[Sh 0] Set Handing of gate

0

0 = gate disabled, r = Right Hand, L = Left Hand

I3

[Fd 0] Load Factory Defaults

0

0 = User settings, 1 = Load defaults (resets full menu)

I3a

[bu 0] Choose Buzzer

0

0 = Buzzer not set, 1 = Freq 1, 2 = Freq. 2

I4

[dg 0] Set Master/Slave type

0

0 = solo operator, 1 = Slave unit, 2 = Master unit

I5

[Ch 0] Set AC Charger or Solar

0

0 = DC + AC charger 1 = DC + Solar charger

I6

[Fo 0] Enable Fire Dept. Open

0

0 = disabled, 1 = enabled

I7

[oC 0] Enable Emergency close

0

0 = disabled, 1 = enabled

I8

[SE 3] Inherent Sensor sens.

3

1 = maximum sensitivity, 9 = Lowest sensitivity

I9

[SS 0] Inherent Sensor function

0

1 = stop only (note, functions in usage class 4 only)

I10

[LC 0] Leaf delay Close

0

0 = none (1-7) ½ second steps (Master/Slave only)

I11

[Lo 0] Leaf delay Open

0

0 = none (1-7) ½ second steps (Master/Slave only)

I12

[rt 0] Maximum run timer

0

0 = 60 Seconds max run, 1 = 300 Seconds max run

I13

[Po 0] Partial Open distance

0

0 = none, or 7 – 99 seconds

I14

[EC 0] PEC reverse to open

0

0 = Close eye stops only, 1 = 2 sec reverse to open

I15

[EO 0] PEO reverse to close

0

0 = Open eye stops only, 1 = 2 sec reverse to close

I16

[gr 0] Edge reverse to open

0

0 = Edge reverses fully open, 1 = 2 sec reversal only

I17

[Sr 1] IES reverse to open

1

0 = IES reverses fully open, 1 = 2 sec reversal only

I18

[PC 0] Set PEO/ PEC – NO/NC

0

0 = Normally Open PE output, 1 = N.C. (supervised)

I19

[gC 0] Set Edge input – NO/NC

0

0 = Normally Open Edge output, 1 = Normally Closed

I20

[tC 1] Time clock/ Interlock input

1

0 = select Time Clock, 1 = select Open Interlock

I20a

[dt 0] Disable Free Exit/Close Tmr

0

0 = disable Free Exit, 1 = disable Close Timer

I21

[or 1] OOLD detector function

1

0 = pause closing only, 1 = enable reversing to open

I22

[ir 1] IOLD detector function

1

0 = pause closing only, 1 = enable reversing to open

I23

[dL 1] Vehicle detector logic

1

1 = std, 2 & 3 = quick close, 4 = full anti-tailgate*

I24

[r1 0] User relay 1 option

1

0 = disabled, 1 – 24 = see output options page 28 - 29

I25

[r2 0] User relay 2 option

6

0 = disabled, 1 – 24 = see output options page 28 - 29

I26

[r3 0] User relay 3 option

1

0 = disabled, 1 – 24 = see output options page 28 - 29

I27

[t L 0] Gate Open alert

2

0 = 0 sec, 1=15s, 2=45s, 3=75s, 4=105s, 5=135s

I28

[Lt 0] Loitering alert

3

0 = 0 sec, 1=15s, 2=45s, 3=75s, 4=105s, 5=135s

I28a

[SA 0] System Address

0

0 = no network, 1-99 = network “drop” address

I29

[ELd0] Test factory ELD*

0

0 = Run mode, 1 = show freq, 2 = show call level 0-7

I30

[iLd0] Test factory IOLD*

0

0 = Run mode, 1 = show freq, 2 = show call level 0-7

I31

[oLd0] Test factory OOLD*

0

0 = Run mode, 1 = show freq, 2 = show call level 0-7

I33

[SLd0] Test factory SLD*

0

0 = Run mode, 1 = show freq, 2 = show call level 0-7

*See page 42 for description of vehicle detector & Loop Fault diagnostics

These Notes Refer to the Menu Above:

I1, I2, I3a These settings must be configured or the gate cannot function and menu will not exit.
I3a The Option bu=0 only appears if the Controller has been reset to factory default settings,
I5 These settings appear only if the factory has provided a DC powered gate operator
I9 IES stop only setting [SS __] does not appear unless set as a class 4 operator
I10, I11 These settings appear only if the Installer Menu is set for Master / Slave function
I27, I28 These settings appear only if the Installer Menu has set relays r1-r3 for these alerts