beautypg.com

Smart touch user menu functions – Controlled Products Systems Group 222X383 User Manual

Page 30

background image

Installation and Maintenance Manual

22

D0119, Rev. F

Smart Touch User Menu Functions

Initial Power Up

– When power is turned on, the display will disclose the software revision:

h4.23

2s delay

Displays software version Number

Software version 4.23 provides the options, adjustments, display code and functionality described in the
remainder of this manual. Older versions may differ slightly. Free Software Upgrades using HySecurity’s
START software are available online at

www.hysecurity.com.


System Data and accessing the User Menu Settings:
If the gate is stopped in the Run Mode, pressing of the Menu button accesses the User Menu. After the menu
button is pressed, the LCD will scroll the system data in the table below. The scrolling display stops at the close
timer setting, which is the beginning of the User Menu. To exit the Menu Mode, the display must not be blinking,
then simply pressing the Menu button will return the display to the Run Mode and re-enable the controls. The
menu mode will also automatically return to the Run Mode if there is no activity for two minutes.

Data Displayed in Scroll Time

Description

S1

[SLAu] or [LEAd]

2s

SLAVE Operator or LEAd Operator (master)

S2

[ot 1] Gate type (1-5)

2s

Operator type: 1 =HSG, 2 =HRG, 3 HVG, 4 =HTG

S3

[_rh_] or [_Lh_] Hand setting

2s

Displays hand configuration [_rh_] or [_Lh_]

S4

[uC _] UL usage class (1-4)

2s

Installer setting of usage class: type 1-4

S5

[d___] 24VDC Buss Voltage

2s

Actual VDC buss voltage

S6

[CC__] Life cycle counter

2s

High digits of 6 digit life cycle counter

S7

[____] Life cycle counter

2s

Last 4 digits of 6 digit life cycle counter


Read through the options available in the User Menu and the Installer Menu on the next page and you can see
that the functions of this gate operator can be configured to suit most any specific need. Once you have
learned to navigate the menus, as described in #3 on page 17-18, and how to change a setting, as described in
#3 & #4 on page 18, the full range of features and choices of the Smart Touch Controller are available to use.
The User Menu contains the basic configuration items and the Installer Menu contains the more advanced
menu items.

User Menu Options

Default

Description

U1

[Ct 0] Close timer setting

0

0 = Close timer off or 1 – 99 seconds

U2

[hC 0] Momentary Close

0

0 = momentary, 1 = Constant hold Close PB required

U3

[ho 0] Momentary Open

0

0 = momentary, 1= Constant hold Open PB required

U4

[AP 0] Power loss function

0

0 – 3 (0=Type A, 1 = B, 2 = C, 3 = D) See page 56

U5

[ro 0] Radio control option

0

0 = Open only, 1 = Adds close ability when full open

U6

[bF 2] Warn before operate

2

0 =off, 1 = Buzzer alerts 3 seconds before + in motion, 2 =
Buzzer alerts 3 secs before + 2 seconds in motion

U7

[FA 0] Forced open Alert and
automatic gate reposition

0

0 = disabled, 1 = sound buzzer (2 pulses/sec) if forced
open for more than four seconds, time out in 30 Sec

U8

[dA 0] Drift Closed Alert and
automatic gate reposition

0

0 = disabled, 1 = sound buzzer (2 pulses/sec) if drift closed
and cannot reopen within four seconds.

U9

[PE 0] Photo Eye Align Mode

0

0= off, 1 = on (auto off when close limit triggered)

U10

[CL 0] Clock set (24 hour type)

0

0= display, 1= set mins, 2= set hours, 3= day, 4= month

U11

[Ld 5] LCD Contrast set

5

1 - 9 = Adjusts contrast of the display

U12

[dS 0] Data Log (New Gen only)

0

0 = Std. 1 = Extended (reset to 0 in 24 hr) (V4.xx software)

These Notes Refer to the Menu Above:

S1 Appears only if the operator is configured as a master or a slave unit
U1 Close timer setting does not appear when set for constant contact close function
U4 Power loss function only appears if factory has provided DC battery type operator
U6 We strongly advise never disabling the Warn Before Operate buzzer.