Installer menu options default description – Controlled Products Systems Group 222X383 User Manual
Page 3
Installation and Maintenance Manual
iii
D0119, Rev. F
Smart Touch Controller Menu Guide for Sliding Gates
To gain access to the User Menu, press the Menu button when the gate is stopped. The LCD will
scroll through several key items, then stop at the close timer setting [Ct ].
User Menu Options
Default
Description
U1
[Ct 0] Close timer setting
0
0 = close timer off or 1 – 99 seconds
U2
[hC 0] Momentary Close
0
0 = momentary, 1= Constant hold PB required to close gate
U3
[ho 0] Momentary Open
0
0 = momentary, 1= Constant hold PB required to open gate
U4
[AP 0] Power loss function
0
0 – 3 (0 =Type A, 1 = B, 2 = C, 3 = D) See handbook
U5
[ro 0] Radio control option
0
0 = Open only, 1 = Adds Close capability when fully open
U6
[bF 2] Warn before operate
2
0 = none, 1 = Buzzer alerts 3 sec before & when in motion,
2 = Buzzer alerts 3 sec before + first 2 seconds in motion
U7
[FA 0] Forced open Alert and
automatic gate reposition
0
0 = disabled, 1 = sound buzzer (2 pulses/sec) if forced
open for more than four seconds, time out in 30 Sec
U8
[dA 0] Drift Closed Alert and
automatic gate reposition
0
0 = disabled, 1 = sound buzzer (2 pulses/sec) if drift closed
and cannot reopen within four seconds.
U9
[PE 0] Photo Eye Align Mode
0
0 = off, 1 = on (auto off when close limit triggered)
U10
[CL 0] Clock set (24 hour type)
0
0= display, 1= set mins, 2= set hours, 3= set day, 4= month
U11
[Ld 5] LCD Contrast set
5
1 - 9 = Adjusts contrast of the display
U12
[dS 0] Data Log (New Gen only)
0
0 = Std. 1 = Extended (resets automatically to 0 in 24 hr)
(V4.xx software)
To access Installer Menu, press the Open & Reset buttons together while in the User Menu.
Installer Menu Options
Default
Description
I1
[uC 0] Set UL Usage Class
0
0 = gate disabled, Set Class 1 through 4 use
I2
[Sh 0] Set Handing of gate
0
0 = gate disabled, r = Right Hand, L = Left Hand
I3
[Fd 0] Load Factory Defaults
0
0 = User settings, 1 = Load defaults (resets entire menu)
I3a
[bu 0] Choose Buzzer Type
0
0 = Buzzer not set, 1 = Freq 1, 2 = Freq 2
I4
[dg 0] Set Master/Slave type
0
0 = Solo operator, 1 = Slave unit, 2 = Master unit
I5
[Ch 0] Set AC Charger or Solar
0
0 = DC + AC charger 1 = DC + Solar charger
I6
[Fo 0] Enable Fire Dept. Open
0
0 = input disabled, 1 = enabled
I7
[oC 0] Enable Emergency close
0
0 = input disabled, 1 = enabled
I8
[SE 3] Inherent Sensor sensitivity
3
1 = Maximum sensitivity, 9 = Lowest sensitivity
I9
[SS 0] Inherent Sensor function
0
1 = stop only (note, functions in usage class 4 only)
I10
[LC 0] Leaf delay Close
0
0 = none (1-7) ½ second steps (Master/slave only)
I11
[Lo 0] Leaf delay Open
0
0 = none (1-7) ½ second steps (Master/slave only)
I12
[rt 0] Maximum run timer
0
0 = 60 Seconds max run, 1 = 300 Seconds max run
I13
[Po 0] Partial Open distance
0
0 = input disabled, or 7 – 99 seconds of travel
I14
[EC 0] PEC reverse to open
0
0 = Close eye stops only, 1 = 2 sec reverse to open
I15
[EO 0] PEO reverse to close
0
0 = Open eye stops only, 1 = 2 sec reverse to close
I16
[gr 0] Edge reverse to open
0
0 = Edge reverses fully open, 1 = Edge reverses for 2 sec
I17
[Sr 1] IES reverse to open
1
0 = IES reverses fully open, 1= IES reverses for 2 sec
I18
[PC 0] Set PEO/ PEC – NO/NC
0
0 = Normally Open PE output, 1 = N.C. (Supervised mode)
I19
[gC 0] Set Edge input – NO/NC
0
0 = Normally Open Edge output, 1 = Normally Closed
I20
[tC 1] Time clock/ Interlock input
1
0 = select Time Clock, 1 = select Open Interlock
I20a
[dt 0] Disable Free Exit/Timer to Close
0
0 = disable Free Exit, 1 = disable Close Timer
I21
[or 1] OOLD detector function
1
0 = pause closing only, 1 = enable reversing to open
I22
[ir 1] IOLD detector function
1
0 = pause closing only, 1 = enable reversing to open
I23
[dL 1] Vehicle detector logic
1
1 = std, 2 & 3 = quick close, 4 = full anti-tailgate logic
I24
[r1 0] User relay 1 option
1
0 = disabled, 1 – 24 = see output options page
I25
[r2 0] User relay 2 option
6
0 = disabled, 1 – 24 = see output options page
I26
[r3 0] User relay 3 option
1
0 = disabled, 1 – 24 = see output options page
I27
[tL 0] Gate Open alert
2
0 = 0 sec, 1 = 15s, 2 = 45s, 3 = 75s, 4 = 105s, 5 = 135s
I28
[Lt 0] Loitering alert
3
0 = 0 sec, 1 = 15s, 2 = 45s, 3 = 75s, 4 = 105s, 5 = 135s
I28a
[SA 0] System Address
0
0 = no network, 1-99 = network “drop” address
I29
[ELd0] Test factory ELD
0
0=Run, 1=show freq, 2=show call level 0-7, 3= set Freq 1-4
I30
[iLd0] Test factory IOLD
0
0=Run, 1=show freq, 2=show call level 0-7, 3= set Freq 1-4
I31
[oLd0] Test factory OOLD
0
0=Run, 1=show freq, 2=show call level 0-7, 3= set Freq 1-4
I32
[SLd0] Test factory SLD
0
0=Run, 1=show freq, 2=show call level 0-7, 3= set Freq 1-4