beautypg.com

Bsc menu, Out1 men out2 men sen menu, Sec menu – Dynasonics TFXM Series Ultrasonic Multi-Channel Flow Meter User Manual

Page 89: Ser menu, Dsp menu, Keypad operations

background image

Date: 3/21/2000
Revision: E Rev. Date: 7/10/2001
Software Version: 1.00.9799

V

V

UNITS
ENGLSH
METRIC

BSC MENU

XDCR MNT
V
W
Z

PIPE OD
ENGLSH (INCHES)
METRIC (MM)

PIPE WT
ENGLSH (INCHES)
METRIC (MM)

PIPE MAT*
CARBON S
STAINLES
CAST IRO
DUCTILE
COPPER
PVC
PVDF LOW
PVDF HI
ALUMINUM
ASBESTOS
FIBERGLASS
OTHER

PIPE SS
ENGLSH (FPS)
METRIC (MPS)

PIPE R
(RELATIVE
ROUGHNESS)

LINER T
ENGLSH (INCHES)
METRIC (MM)

OUT1 MEN

OUT2 MEN

SEN MENU

NOT USED

SEC MENU

TOT RES

NO

YES

SYS RSET

NO

YES

CH PSWD?

0-9999

SER MENU

SSPD MPS

SSPD FPS

OUT1

OPTIONS

4-20MA

FL 4MA

FL 20MA

4-20 TST

RELAY

RELAY 1

RELAY 2

RTD

CAL 1

CAL 2

A

B

C

RS232

RS232 MO

HOST

UIF

RS232 BA

1200

2400

9600

19200

RS485

RS485 MO

SLAVE

MASTER

RS485 BA

1200

2400

9600

19200

ADDRESS

1-127

NONE

SIG STR

DSP MENU

DISPLAY
FLOW
TOTAL
BOTH

SCN DWL
1-10

Keypad Operations

1.

The MENU key is pressed from RUN mode to enter PROGRAM mode.
The MENU key is pressed in PROGRAM mode to exit configuration
parameters and menus. If changes to any configuration parameters have
been made, the user will be prompted with a SAVE?YES when returning to
RUN mode.

2.

The ARROW keys are used to scroll through menus and configuration
parameters. The ARROW keys are also used to adjust parameter
numerical values.

3.

The ENTER key is

??

pressed from the RUN mode to view the current software version operating
in the instrument.

??

used to access the configuration parameters in the various menus.

??

Used to initiate changes in configuration parameters.

??

Used to accept configuration parameter changes.

TOTL UNT
GALLONS
LITERS
MGAL
CUBIC FT
CUBIC ME
ACRE FT
OIL BARR
LIQ BARR
FEET
METERS

TOTL E
E-1 TO E6

MIN RATE
RATE/INT

MAX RATE
RATE/INT

FL C-OFF
% of Full Scale

DAMP PER
PERCENT

LINER TYPE*
TAR EPOXY
RUBBER
MORTAR
POLYPROPYLENE
POLYSTYROL
POLYSTYRENE
POLYESTER
TEFLON
OTHER

FL TYPE*
TAP WATER
SEWAGE
KEROSENE
GASOLINE
FUEL OIL
CRUDE OI
PROPANE
BUTANE
OTHER

FLUID SS
ENGLSH (FPS)
METRIC (MPS)

FLUID VI
CPS

SP GRVTY
UNITLESS

RATE INT
MIN
HOUR
DAY
SEC

XDC SPAC
ENGLSH (INCHES)
METRIC (MM)

RATE UNT
GALLONS
LITERS
MGAL
CUBIC FT
CUBIC ME
ACRE FT
OIL BARR
LIQ BARR
FEET
METERS

LINER SS
ENGLSH (FPS)
METRIC (MPS)

*List provided for example only. Additional entries may be available.

SIG C-OFF

SUB FLOW

SET ZERO

0-10KHz

FL 100H

FL 10KH

OUT2

OPTIONS

4-20MA

FL 4MA

FL 20MA

4-20 TST

RELAY

RELAY 1

RELAY 2

RTD

CAL 1

CAL 2

A

B

C

RS232

RS232 MO

HOST

UIF

RS232 BA

1200

2400

9600

19200

RS485

RS485 MO

SLAVE

MASTER

RS485 BA

1200

2400

9600

19200

ADDRESS

1-127

NONE

0-10KHz

FL 100H

FL 10KH

TOTAL
NET
POS
NEG
BATCH

D-FLT 0

COR FTR

SP HEAT
NOMINAL
HEAT CAPACITY

BTCH MUL
TOTALIZER UNIT
W/ TOTAL E