Bsc menu, Out1 men out2 men sen menu, Sec menu – Dynasonics TFXM Series Ultrasonic Multi-Channel Flow Meter User Manual
Page 89: Ser menu, Dsp menu, Keypad operations

Date: 3/21/2000
Revision: E Rev. Date: 7/10/2001
Software Version: 1.00.9799
V
V
UNITS
ENGLSH
METRIC
BSC MENU
XDCR MNT
V
W
Z
PIPE OD
ENGLSH (INCHES)
METRIC (MM)
PIPE WT
ENGLSH (INCHES)
METRIC (MM)
PIPE MAT*
CARBON S
STAINLES
CAST IRO
DUCTILE
COPPER
PVC
PVDF LOW
PVDF HI
ALUMINUM
ASBESTOS
FIBERGLASS
OTHER
PIPE SS
ENGLSH (FPS)
METRIC (MPS)
PIPE R
(RELATIVE
ROUGHNESS)
LINER T
ENGLSH (INCHES)
METRIC (MM)
OUT1 MEN
OUT2 MEN
SEN MENU
NOT USED
SEC MENU
TOT RES
NO
YES
SYS RSET
NO
YES
CH PSWD?
0-9999
SER MENU
SSPD MPS
SSPD FPS
OUT1
OPTIONS
4-20MA
FL 4MA
FL 20MA
4-20 TST
RELAY
RELAY 1
RELAY 2
RTD
CAL 1
CAL 2
A
B
C
RS232
RS232 MO
HOST
UIF
RS232 BA
1200
2400
9600
19200
RS485
RS485 MO
SLAVE
MASTER
RS485 BA
1200
2400
9600
19200
ADDRESS
1-127
NONE
SIG STR
DSP MENU
DISPLAY
FLOW
TOTAL
BOTH
SCN DWL
1-10
Keypad Operations
1.
The MENU key is pressed from RUN mode to enter PROGRAM mode.
The MENU key is pressed in PROGRAM mode to exit configuration
parameters and menus. If changes to any configuration parameters have
been made, the user will be prompted with a SAVE?YES when returning to
RUN mode.
2.
The ARROW keys are used to scroll through menus and configuration
parameters. The ARROW keys are also used to adjust parameter
numerical values.
3.
The ENTER key is
??
pressed from the RUN mode to view the current software version operating
in the instrument.
??
used to access the configuration parameters in the various menus.
??
Used to initiate changes in configuration parameters.
??
Used to accept configuration parameter changes.
TOTL UNT
GALLONS
LITERS
MGAL
CUBIC FT
CUBIC ME
ACRE FT
OIL BARR
LIQ BARR
FEET
METERS
TOTL E
E-1 TO E6
MIN RATE
RATE/INT
MAX RATE
RATE/INT
FL C-OFF
% of Full Scale
DAMP PER
PERCENT
LINER TYPE*
TAR EPOXY
RUBBER
MORTAR
POLYPROPYLENE
POLYSTYROL
POLYSTYRENE
POLYESTER
TEFLON
OTHER
FL TYPE*
TAP WATER
SEWAGE
KEROSENE
GASOLINE
FUEL OIL
CRUDE OI
PROPANE
BUTANE
OTHER
FLUID SS
ENGLSH (FPS)
METRIC (MPS)
FLUID VI
CPS
SP GRVTY
UNITLESS
RATE INT
MIN
HOUR
DAY
SEC
XDC SPAC
ENGLSH (INCHES)
METRIC (MM)
RATE UNT
GALLONS
LITERS
MGAL
CUBIC FT
CUBIC ME
ACRE FT
OIL BARR
LIQ BARR
FEET
METERS
LINER SS
ENGLSH (FPS)
METRIC (MPS)
*List provided for example only. Additional entries may be available.
SIG C-OFF
SUB FLOW
SET ZERO
0-10KHz
FL 100H
FL 10KH
OUT2
OPTIONS
4-20MA
FL 4MA
FL 20MA
4-20 TST
RELAY
RELAY 1
RELAY 2
RTD
CAL 1
CAL 2
A
B
C
RS232
RS232 MO
HOST
UIF
RS232 BA
1200
2400
9600
19200
RS485
RS485 MO
SLAVE
MASTER
RS485 BA
1200
2400
9600
19200
ADDRESS
1-127
NONE
0-10KHz
FL 100H
FL 10KH
TOTAL
NET
POS
NEG
BATCH
D-FLT 0
COR FTR
SP HEAT
NOMINAL
HEAT CAPACITY
BTCH MUL
TOTALIZER UNIT
W/ TOTAL E