beautypg.com

Part 3 - keypad configuration – Dynasonics TFXM Series Ultrasonic Multi-Channel Flow Meter User Manual

Page 45

background image


Rev. 8/02

-3. 7-

TFXM

PIPE MAT -- Pipe Material Selection

CARBON S - Carbon Steel

STAINLES - Stainless Steel

CAST IRO - Cast Iron

DUCTILE - Ductile Iron

COPPER - Copper

PVC - Polyvinylchloride

PVDF LOW -

Low Density Polyvinylidene Flouride

PVDF HI -

High Density Polyvinylidene Flouride

ALUMINUM - Aluminum

ASBESTOS - Asbestos Cement

FIBERGLA - Fiberglass

OTHER


This list is provided as an example. Additional pipe materials
are being added continuously. Select the appropriate pipe
material from the list or select OTHER if the material is not
listed.



PIPE SS -- Speed of Sound in the Pipe Material

ENGLSH (Feet per Second)

METRIC (Meters per Second)


Allows adjustments to be made to the speed of sound in the
pipe wall. If the UNITS value was set to ENGLSH, the entry is
in FPS (feet per second). METRIC entries are made in MPS
(meters per second).

If a pipe material was chosen from the PIPE MAT list, a
nominal value for speed of sound in that material will be
automatically loaded. If the actual sound speed rate is known
for the application piping system and that value varies from the
automatically loaded value, the value can be revised.

If OTHER was chosen as PIPE MAT, a PIPE SS will need to
be entered.

PART 3 - KEYPAD CONFIGURATION

Pipe Sound
Speed

Pipe Material