Part 3 - keypad configuration – Dynasonics TFXM Series Ultrasonic Multi-Channel Flow Meter User Manual
Page 45

Rev. 8/02
-3. 7-
TFXM
PIPE MAT -- Pipe Material Selection
CARBON S - Carbon Steel
STAINLES - Stainless Steel
CAST IRO - Cast Iron
DUCTILE - Ductile Iron
COPPER - Copper
PVC - Polyvinylchloride
PVDF LOW -
Low Density Polyvinylidene Flouride
PVDF HI -
High Density Polyvinylidene Flouride
ALUMINUM - Aluminum
ASBESTOS - Asbestos Cement
FIBERGLA - Fiberglass
OTHER
This list is provided as an example. Additional pipe materials
are being added continuously. Select the appropriate pipe
material from the list or select OTHER if the material is not
listed.
PIPE SS -- Speed of Sound in the Pipe Material
ENGLSH (Feet per Second)
METRIC (Meters per Second)
Allows adjustments to be made to the speed of sound in the
pipe wall. If the UNITS value was set to ENGLSH, the entry is
in FPS (feet per second). METRIC entries are made in MPS
(meters per second).
If a pipe material was chosen from the PIPE MAT list, a
nominal value for speed of sound in that material will be
automatically loaded. If the actual sound speed rate is known
for the application piping system and that value varies from the
automatically loaded value, the value can be revised.
If OTHER was chosen as PIPE MAT, a PIPE SS will need to
be entered.
PART 3 - KEYPAD CONFIGURATION
Pipe Sound
Speed
Pipe Material