(RI) RFID Configuration
– This command configures the optional RFID interface module, as follows:
Table 5-8: RFID Configuration Set Commands
Value
Units / Interpretation
RFID Configuration Definition / Function
D = Disable
Disables the RFID module. (“N” is also a valid disabler.)
H = HF
Enables the RFID module for HF (Securakey).
U = UHF
Enables the RFID module for UHF Class 1 (Alien).
Mn
where n:
M = UHF
Enables the RFID module for UHF Multi-Protocol (Samsys).
AIhh
where hh:
2-Chararacter Hex ID Sets the Application Family Identifier (AFI), (HF only)
ALn
and where n:
E = Enable,
D = Disable
Allows locking the AFI after writing (HF only)
DIhh
where hh:
2-Chararacter Hex ID Sets the Data Storage Format Identifier (DSFID), (HF only)
DLn
and where n:
E = Enable,
D = Disable
Allows locking the DSFID after writing (HF only)
Shh
where hh:
2-Chararacter Hex ID Sets the Electronic Article Surveillance (EAS) set, representing the manufacturer’s code. (HF only)
Lhh
where hh:
2-Chararacter Hex ID Sets the Lock Code (Alien UHF only)
Rn
where n:
0 – 9
Sets the number of retries for RFID functions
Wn
where n:
E = Enable,
D = Disable
Allows locking the tag after writing.
En
where n:
E = Enable,
D = Disable
Allows erasures of the tag on error (HF only)
Pxxx
where xxx: 3-digit
value
Sets the tag encoding position: A value of 0.00 causes the print position to be used; or, a value
greater than 0 causes the presented position to be used. (Subject to change.)