beautypg.com

Stx kx delete configuration file, Stx kz immediately set parameter – Datamax-O'Neil Class Series Programmer’s Manual User Manual

Page 122

background image

Extended System-Level Command Functions






Class Series Programmer’s Manual

108

STX Kx

Delete Configuration File

(Display-Equipped Models only)

This command deletes the specified configuration file.

Syntax:

KxmName

Where:

m

-

Valid Module ID – Range A to Z.

Name

-

The name, up to 16 characters, of the configuration file.

-

0x0d terminates the name.

Sample:

KxYPlant1

This command deletes the configuration file Plant1 located on Module Y. (Remember to prefix this
command with the Module (Un)Protect Command Kp.)






STX KZ

Immediately Set Parameter

This command immediately sets the specified parameter.

Syntax:

KZax

Where:

a

-

Valid parameter identifier, as follows:

F =

Feed Speed

H =

Heat Setting

P =

Print Speed

S =

Slew Speed

x

- Speed Parameter Range – A to e (see Appendix L).

-or-

xx

-

Heat Parameter Range – A two-digit value (00-30); see the
‘H’ Label Formatting Command.

Sample:

KZH22

This command causes the file currently being executed to assume a Heat Value of 22.