Example:
The command string above is typical of a network setup string (where the values meanings are
shown in the following table). This configuration setup command string may be included with
any other Kc sub-commands.
Sub-commands and Values
Interpretation
NTI010.012.000.243
IP Address: 10.12.0.243
NTS255.255.000.000
Subnet Mask: 255.255.0.0
NTG010.012.254.254
Gateway Address: 10.12.254.254
NTDN
DHCP is disabled
(NR) No Reprint – This command controls the label reprint function following the correction of a
fault condition. Upon detection of a fault (ribbon out, paper out, etc.), printing stops and a fault
indicator is illuminated. After the problem is corrected, the FEED Key must be pressed to clear
the fault and resume normal operation. When enabled, the label in process is not reprinted.
(NS) Disable Symbol Set Selection – This command prevents the
from changing the default single-byte symbol set. When enabled, DPL Symbol Set commands are
ignored.
Note: When enabled, the only way to change the current symbol set is with the
command.