STX Y

Output Sensor Values

This command causes a sensor value response. When Y is received, the printer will respond
with the digitally converted values of the internal analog sensors (see below). To repeat the display of
values, send the printer a ‘SPACE’ character (20 hexadecimal); or, send to terminate this
function.

Non-Display Models: The printer must be in Test Mode for the command to function. To enable the
Test Mode see the KD command.

Display-Equipped Models: The printer must have Feedback Characters enabled for this command to
function. (Feedback Mode [Characters] can be enabled via command or menu setting; see the
KcFM command or the Operator’s Manual for additional information).

Syntax:

Y

Printer response:

Thermistor ADC: 0048 Reflective ADC: 0000
Transmissive ADC: 0204 Paperout ADC: 0000 24 Volt ADC:
0217 Contrast ADC: 0093 TOF Adjust ADC: 0170 Ribbon
ADC: 0125 Battery Level: Good

Where:

Paperout ADC:

0225

indicates paper is present;

0000

indicates paper is not present.

Battery level:

Good

indicates a sufficient battery charge;

Low

indicates an insufficient charge.

Notes:

Equipped sensors may vary with printer, model, and options.

Some readings require printer-controlled paper movement to produce a meaningful value.

Media Sensor readings require the appropriate sensor selection, transmissive (

e

)

or

reflective (

r

)

, and label stock in the Media Sensor.


STX y

Select Font Symbol Set

This command selects the scalable font symbol set. The selected symbol set remains active until
another symbol set is selected. See the KS command and Appendices E, I, and H for more
information. Option dependant, and not all symbol sets can be used with all fonts.

Syntax:

ySxx

Where:

S

-

Byte-size designation; see Appendix H:

S

= Single byte symbol sets.

U = Double byte symbol sets.

xx

-

Symbol set selection.

Sample:

ySPM

The sample selects the PC-850 multilingual set.