Extended System-Level Command Functions
Class Series Programmer’s Manual
107
STX KuW Write Data to RFID Tag
(Direct Mode – UHF Interface – Hexadecimal Data Only)
This command instructs the RFID device to write data to the tag. It is expected that the tag
transponder will be within the read / write distance of the RFID programming device; otherwise, a
warning will occur and a warning message (Read / Write Fail) will be displayed.
Syntax:
a
- The number of attempts to locate, erase, and program the tag, 1-9.
b
- Reserved. Should be 0.
Where:
cc…c
- Data to be encoded in the ASCII format. Must be sixteen
characters in length. The valid characters are 0-9, A-F.
Note: Must be 16 or 24 characters long.
Sample:
The sample programs the data <0xAB><0xCD><0xEF><0x01><0x02><0x03><0x04><0x05>
to the tag, attempting to write one additional time if necessary.
STX KV
Verifier Enable/Disable
(Display-Equipped Models only)
This command allows the verifier (option, if installed), to be enabled and disabled.
Syntax:
Where:
a
-
Y
= verifier enable
N = verifier disable
STX KW
Memory Configuration, Printable Label Width
(Non-Display Models only)
See the
Note: This command will result in a system reset for the EX2.